This page describes the device driver and the device window for the Agilis integrated BUC / SSPA over SNMP
The driver was tested with
The driver was tested with the following SW Releases:
BUC: 102,109,116
SSPA: 113,114,116
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- The transmit parameters
--- Displays meter readings like output power and BUC specific measurements.
--- Displays the redundancy settings
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the amplifier.
parameter --- description
address --- The SNMP address specification for the device. The full address specification consists of the following fields:aaa.bbb.ccc.ddd:pppp read-community write-community
powerDisplayMode --- Defines the display of gain or attenuation in the parameter section.
startup --- Defines the default startup condition for the BUCs transmit state.
frequency --- Defines the used lo frequency if the unit is equipped with more than one upconverter frequency.
bucNumber --- Defines the identifier of the BUC in a 1:1 redundancy 1 or 2
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| config.startup | CHOICE | SETUP | EnumRange (ON OFF) |
| config.frequency | CHOICE | SETUP | EnumRange (FIXED LO LO-1 LO-2) |
| config.bucNumber | CHOICE | SAVE SETUP | EnumRange (1 2) |
| info.model | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.versionBuc | TEXT | R/O | StringRange R/O |
| info.versionSspa | TEXT | R/O | StringRange R/O |
| info.redundancy | CHOICE | R/O | EnumRange R/O (ON OFF) |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| tx.measuredLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| rx.measuredLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| tx.on | CHOICE | EnumRange (OFF ON) | |
| tx.gain | FLOAT | DoubleRange (0.0 .. 20.0) | |
| tx.attn | FLOAT | DoubleRange (0.0 .. 20.0) | |
| meas.refPwr | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.fwdPwr | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.measuredLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.temperature | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| protection | CHOICE | EnumRange DIS (MANUAL AUTO) | |
| position | CHOICE | R/O | EnumRange R/O DIS (A B) |
| location | CHOICE | EnumRange DIS (ONLINE STANDBY) | |
| internal.on | TEXT | R/O | StringRange R/O |
| internal.pout | TEXT | R/O | StringRange R/O |
| internal.pin | TEXT | R/O | StringRange R/O |
| internal.pref | TEXT | R/O | StringRange R/O |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (LO Lock) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (FET Bias) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (High RF) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Low RF) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Temperature) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Reflected Power) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (RF Module) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Protection) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (TX Off) |