1.17 ASCSignal-NGC-RedundancyModule

This page describes an addon device driver and the device window for the ASC Signal NGC ACU redundancy module

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the antenna controller.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.overallConfig TEXT R/O StringRange R/O
info.block1Config TEXT R/O StringRange R/O
info.block2Config TEXT R/O StringRange R/O
info.block1Name TEXT R/O StringRange R/O
info.block2Name TEXT R/O StringRange R/O
info.block1Type TEXT R/O StringRange R/O
info.block2Type TEXT R/O StringRange R/O
internal.pos1 CHOICE R/O EnumRange R/O (F A B)
internal.pos2 CHOICE R/O EnumRange R/O (F A B)
internal.flt INTEGER R/O IntegerRange R/O (0 .. 0)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
meas.current.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.2 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.3 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.4 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.voltage.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.3 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.4 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.bus1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.bus2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
state CHOICE EnumRange (ABSENT DISABLED FAULT OPERATIONAL)
reset TEXT NOPRESET StringRange
current.margin INTEGER IntegerRange (0 .. 2000)
nom.current.1 INTEGER IntegerRange (0 .. 2000)
nom.current.2 INTEGER IntegerRange (0 .. 2000)
nom.current.3 INTEGER IntegerRange (0 .. 2000)
nom.current.4 INTEGER IntegerRange (0 .. 2000)
protection.1 CHOICE EnumRange (MANUAL AUTO)
protection.2 CHOICE EnumRange (MANUAL AUTO)
position CHOICE EnumRange (3-STBY 1-STBY 2-STBY)
position.1 CHOICE R/O EnumRange R/O (A B)
position.2 CHOICE R/O EnumRange R/O (A B)
faults.01 ALARM R/O AlarmFlagRange R/O (Main power supply)
faults.02 ALARM R/O AlarmFlagRange R/O (Red. power supply)
faults.03 ALARM R/O AlarmFlagRange R/O (Switch 1)
faults.04 ALARM R/O AlarmFlagRange R/O (Switch 2)
faults.05 ALARM R/O AlarmFlagRange R/O (Switched)
faults.06 ALARM R/O AlarmFlagRange R/O (Protection block 1)
faults.07 ALARM R/O AlarmFlagRange R/O (Protection block 2)
faults.08 ALARM R/O AlarmFlagRange R/O (Redundancy Module)
faults.11 ALARM R/O AlarmFlagRange R/O (LNA/LNB1)
faults.12 ALARM R/O AlarmFlagRange R/O (LNA/LNB2)
faults.13 ALARM R/O AlarmFlagRange R/O (LNA/LNB3)
faults.14 ALARM R/O AlarmFlagRange R/O (LNA/LNB4)
faults.15 ALARM R/O AlarmFlagRange R/O (Unit 1 Fuse)
faults.16 ALARM R/O AlarmFlagRange R/O (Unit 2 Fuse)
faults.17 ALARM R/O AlarmFlagRange R/O (Unit 3 Fuse)
faults.18 ALARM R/O AlarmFlagRange R/O (Unit 4 Fuse)
faults.19 ALARM R/O AlarmFlagRange R/O (Unit 1 Low Current)
faults.20 ALARM R/O AlarmFlagRange R/O (Unit 2 Low Current)
faults.21 ALARM R/O AlarmFlagRange R/O (Unit 3 Low Current)
faults.22 ALARM R/O AlarmFlagRange R/O (Unit 4 Low Current)
faults.23 ALARM R/O AlarmFlagRange R/O (Unit 1 High Current)
faults.24 ALARM R/O AlarmFlagRange R/O (Unit 2 High Current)
faults.25 ALARM R/O AlarmFlagRange R/O (Unit 3 High Current)
faults.26 ALARM R/O AlarmFlagRange R/O (Unit 4 High Current)
faults.27 ALARM R/O AlarmFlagRange R/O (Unit 1 External)
faults.28 ALARM R/O AlarmFlagRange R/O (Unit 2 External)
faults.29 ALARM R/O AlarmFlagRange R/O (Unit 3 External)
faults.30 ALARM R/O AlarmFlagRange R/O (Unit 4 External)
faults.31 ALARM R/O AlarmFlagRange R/O (LNA/LNB1 Latched)
faults.32 ALARM R/O AlarmFlagRange R/O (LNA/LNB2 Latched)
faults.33 ALARM R/O AlarmFlagRange R/O (LNA/LNB3 Latched)
faults.34 ALARM R/O AlarmFlagRange R/O (LNA/LNB4 Latched)
faults.35 ALARM R/O AlarmFlagRange R/O (Unit 1 Fuse Latched)
faults.36 ALARM R/O AlarmFlagRange R/O (Unit 2 Fuse Latched)
faults.37 ALARM R/O AlarmFlagRange R/O (Unit 3 Fuse Latched)
faults.38 ALARM R/O AlarmFlagRange R/O (Unit 4 Fuse Latched)
faults.39 ALARM R/O AlarmFlagRange R/O (Unit 1 Low Current Latched)
faults.40 ALARM R/O AlarmFlagRange R/O (Unit 2 Low Current Latched)
faults.41 ALARM R/O AlarmFlagRange R/O (Unit 3 Low Current Latched)
faults.42 ALARM R/O AlarmFlagRange R/O (Unit 4 Low Current Latched)
faults.43 ALARM R/O AlarmFlagRange R/O (Unit 1 High Current Latched)
faults.44 ALARM R/O AlarmFlagRange R/O (Unit 2 High Current Latched)
faults.45 ALARM R/O AlarmFlagRange R/O (Unit 3 High Current Latched)
faults.46 ALARM R/O AlarmFlagRange R/O (Unit 4 High Current Latched)
faults.47 ALARM R/O AlarmFlagRange R/O (Unit 1 External Latched)
faults.48 ALARM R/O AlarmFlagRange R/O (Unit 2 External Latched)
faults.49 ALARM R/O AlarmFlagRange R/O (Unit 3 External Latched)
faults.50 ALARM R/O AlarmFlagRange R/O (Unit 4 External Latched)
faults.51 ALARM R/O AlarmFlagRange R/O (Redundancy 1-1)
faults.52 ALARM R/O AlarmFlagRange R/O (Redundancy 1-2)
faults.53 ALARM R/O AlarmFlagRange R/O (Redundancy 1-3)
faults.54 ALARM R/O AlarmFlagRange R/O (Redundancy 1-4)
faults.55 ALARM R/O AlarmFlagRange R/O (Redundancy 2-1)
faults.56 ALARM R/O AlarmFlagRange R/O (Redundancy 2-2)
faults.57 ALARM R/O AlarmFlagRange R/O (Redundancy 2-3)
faults.58 ALARM R/O AlarmFlagRange R/O (Redundancy 2-4)
faults.59 ALARM R/O AlarmFlagRange R/O (Redundancy 3-1)
faults.60 ALARM R/O AlarmFlagRange R/O (Redundancy 3-2)
faults.61 ALARM R/O AlarmFlagRange R/O (Redundancy 3-3)
faults.62 ALARM R/O AlarmFlagRange R/O (Redundancy 3-4)
faults.63 ALARM R/O AlarmFlagRange R/O (Redundancy 4-1)
faults.64 ALARM R/O AlarmFlagRange R/O (Redundancy 4-2)
faults.65 ALARM R/O AlarmFlagRange R/O (Redundancy 4-3)
faults.66 ALARM R/O AlarmFlagRange R/O (Redundancy 4-4)
faults.67 ALARM R/O AlarmFlagRange R/O (Switch 1-1)
faults.68 ALARM R/O AlarmFlagRange R/O (Switch 1-2)
faults.69 ALARM R/O AlarmFlagRange R/O (Switch 2-1)
faults.70 ALARM R/O AlarmFlagRange R/O (Switch 2-2)
faults.71 ALARM R/O AlarmFlagRange R/O (Switch 3-1)