The Auto-RollOff logical device adds an automatic roll-off selection to IRDs which lack from this feature or which do not behave properly with the roll-off set to AUTO.
The Auto-RollOff device is linked to an IRD's rollOff and symbolRate parameters, it provides an rollOff parameter which the GUI uses instead of the IRD's one. The device's rollOff parameter offers the same selections as the the parameter at the IRD, with an AUTO setting added.
If the rollOff parameter is set to one of the 20%, 25% or 35% settings, this value is passed to the IRD. If set to AUTO, the device computes and sets the rollOff setting from the symbol rate using these formulas:
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- Sets the roll of factor
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters from this page are described below.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameter which must be set to interconnect the Auto-RollOff device with the IRD device.
| parameter | description |
|---|---|
| rollOffId | Enter the message identifier here of the IRD's roll off parameter, e.g. "IRD-3.rollOff". |
| outputId | Enter the message identifier here of the IRD's symbol rate parameter, e.g. "IRD-3.symbolRate". |
| bandwidthSteps | This parameter defines the stepping of allocated bandwidth as a comma separated list of values. Factory default is "3,4.5,6,9,12,18,24,27,36". For detail about specifying the list of allocated bandwidths see the paragraph below. |
List of allocated bandwidths
The device provides a setup parameter to specify the list of allocated bandwidth value to use. When specifying this list, the following rules apply:
Fault flags
The Auto-RollOff device provides one fault flag which is raised if in AUTO mode a symbol rate is recognized which occupies a bandwidth wider than the widest allocated slot, even with 20% roll off set. The flag remains active until a valid symbol rate is set at the IRD.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.rollOff | TEXT | R/O | StringRange R/O |
| info.symbolRate | FLOAT | R/O | DoubleRange R/O (0.000000 .. 0.000000) |
| config.rollOffId | TEXT | SAVE SETUP | StringRange |
| config.symbolRateId | TEXT | SAVE SETUP | StringRange |
| config.bandwidthSteps | TEXT | SAVE SETUP | StringRange |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Invalid symbol rate) |
| rollOff | CHOICE | NOPRESET | EnumRange (UNKNOWN) |