1.109 CandM-Switch-30510

This page describes the device driver and the device window for the C&M Systems Microwave Waveguide Switching system controller: Model CM30510 with up to 2 waveguide switches but without any HPA or KPA redundancy.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address The device address (decimal) as set at the device's front panel.
Serial Remember to set the line parameters for the serial interface
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
reset TEXT NOPRESET StringRange
switch.01 CHOICE EnumRange (A B FLT)
switch.02 CHOICE EnumRange (A B FLT)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.03 ALARM R/O AlarmFlagRange R/O (PSU 1)
faults.04 ALARM R/O AlarmFlagRange R/O (PSU 2)
faults.05 ALARM R/O AlarmFlagRange R/O (AC1 5V)
faults.06 ALARM R/O AlarmFlagRange R/O (AC2 5V)
faults.07 ALARM R/O AlarmFlagRange R/O (AC1 30V)
faults.08 ALARM R/O AlarmFlagRange R/O (AC2 30V)
faults.21 ALARM R/O AlarmFlagRange R/O (Switch 1)
faults.22 ALARM R/O AlarmFlagRange R/O (Switch 2)