1.143 Comtech-LPOD-SNMP

This page describes the device driver and the device window for the Comtech LPOD block upconverter over SNMP.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.extRef CHOICE SETUP EnumRange (DISABLED ENABLED)
config.faultRecovery CHOICE SETUP EnumRange (MANUAL AUTO)
config.lnbPower CHOICE SETUP EnumRange (DISABLE NO-TONE 18V TONE-18V NO-TONE-13V TONE-13V)
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.partno TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.vdc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
tx.amplifier CHOICE EnumRange (OFF ON)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.00 .. 20.00)
tx.attn FLOAT DoubleRange (0.00 .. 20.00)
reset TEXT NOPRESET StringRange
protection CHOICE EnumRange (OFF 1+1 TX 1+1 TX/RX 1+2 TX 1+2 TX/RX MANUAL)
location CHOICE NOPRESET EnumRange (ONLINE OFFLINE)
internal.x1 TEXT R/O StringRange R/O
internal.x2 TEXT R/O StringRange R/O
internal.pout FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.on TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (BUC lock detect)
faults.02 ALARM R/O AlarmFlagRange R/O (Ref lock detect)
faults.03 ALARM R/O AlarmFlagRange R/O (FPGA done)
faults.04 ALARM R/O AlarmFlagRange R/O (Flash checksum)
faults.05 ALARM R/O AlarmFlagRange R/O (Forward power)
faults.06 ALARM R/O AlarmFlagRange R/O (Reverse power)
faults.07 ALARM R/O AlarmFlagRange R/O (Overtemp shutdown)
faults.08 ALARM R/O AlarmFlagRange R/O (Amplifier temp)
faults.09 ALARM R/O AlarmFlagRange R/O (FAN 1)
faults.10 ALARM R/O AlarmFlagRange R/O (FAN 2)
faults.11 ALARM R/O AlarmFlagRange R/O (24V power supply)
faults.12 ALARM R/O AlarmFlagRange R/O (24V switch power supply)
faults.13 ALARM R/O AlarmFlagRange R/O (13V power supply)
faults.14 ALARM R/O AlarmFlagRange R/O (7.8V power supply)
faults.15 ALARM R/O AlarmFlagRange R/O (5.8V power supply)
faults.16 ALARM R/O AlarmFlagRange R/O (2.5V power supply)
faults.17 ALARM R/O AlarmFlagRange R/O (1.2V power supply)
faults.18 ALARM R/O AlarmFlagRange R/O (-5.8V power supply)
faults.26 ALARM R/O AlarmFlagRange R/O (TX OFF)