1.86 CPI-KHPA-G4

This page describes the device driver and the device window for the CPI Klystron amplifiers Generation 4.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Amplifier.

parameter description
address The device address (decimal). The factory default is 48
lowLimitAlarm The low output power alarm trip point.
highLimitAlarm The high output power alarm trip point.
lowLimitFault The low output power fault trip point.
highLimitFault The high output power fault trip point.
Serial Remember to set the line parameters for the serial interface. of the HPA is 9600,E,7,1 .
redundancy Configures the operation mode of the internal redundancy switching logic of the amplifier.
logGainChanges Defines if gain changes should be written in the event log database. Can automatically be adjusted by logLevelEnabledId within Uplink Power Control

Serial Interface

You can configure the line setting on the front panel. This includes also the selection of RS232 or RS485.

Channel Changer

If the Klystron is equipped with an channel changer you have to configure the number of channels on the front panel of the HPA. Then the M&C system is able to detect this via the ID/Version Query and the driver will enable the channel field. If the Klystron is not equipped with an channel changer, set the number of channels on the front panel to 0 and the driver will not allow to select a channel.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.maxChannels INTEGER R/O IntegerRange R/O (0 .. 50)
info.signal.on BOOLEAN R/O BooleanRange R/O (true false)
firstRun INTEGER R/O IntegerRange R/O (0 .. 0)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.lowLimitAlarm INTEGER SETUP IntegerRange (0 .. 3100)
config.highLimitAlarm INTEGER SETUP IntegerRange (0 .. 3100)
config.lowLimitFault INTEGER SETUP IntegerRange (0 .. 3100)
config.highLimitFault INTEGER SETUP IntegerRange (0 .. 3100)
config.redundancy CHOICE SAVE SETUP EnumRange (STANDALONE 1:1 2:1 MAIN 2:1 BACKUP)
config.logGainChanges CHOICE SAVE SETUP EnumRange (ON OFF)
config.deviceComment TEXT SAVE SETUP StringRange
tx.channelSelect CHOICE EnumRange DIS (0)
tx.on CHOICE EnumRange (OFF ON)
tx.beam CHOICE EnumRange (STANDBY 1KV STBY ON)
tx.gain FLOAT DoubleRange (0.0 .. 25.5)
tx.attn FLOAT DoubleRange (0.0 .. 25.5)
reset TEXT NOPRESET StringRange
state TEXT R/O StringRange R/O
tx.measuredLevel FLOAT R/O DoubleRange R/O (-100.0 .. 40.0)
tx.requestedLevel FLOAT SAVE DoubleRange (-100.0 .. 40.0)
tx.adjustInProgress BOOLEAN R/O BooleanRange R/O (true false)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.refPwr INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.uBeam FLOAT R/O DoubleRange R/O (0.00 .. 100.00)
meas.iBeam FLOAT R/O DoubleRange R/O (0.00 .. 10.00)
meas.iBody FLOAT R/O DoubleRange R/O (0.0 .. 1000.0)
meas.uHeater FLOAT R/O DoubleRange R/O (0.0 .. 100.0)
meas.iHeater FLOAT R/O DoubleRange R/O (0.0 .. 100.0)
meas.drive INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.temp INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.inletTemp INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.outletTemp INTEGER R/O IntegerRange R/O (0 .. 1000)
protection CHOICE EnumRange (MANUAL AUTO)
position.01 CHOICE EnumRange (A B N/A)
position.02 CHOICE EnumRange (A B N/A)
position.03 CHOICE EnumRange (A B N/A)
position.04 CHOICE EnumRange (A B N/A)
position.05 CHOICE EnumRange (A B N/A)
position.06 CHOICE EnumRange (A B N/A)
position.07 CHOICE EnumRange (A B N/A)
position.08 CHOICE EnumRange (A B N/A)
position.09 CHOICE EnumRange (A B N/A)
position.10 CHOICE EnumRange (A B N/A)
internal.dummy FLOAT R/O DoubleRange R/O (0 .. 0)
internal.summ INTEGER R/O IntegerRange R/O (0 .. 0)
internal.bsl INTEGER R/O IntegerRange R/O (0 .. 0)
internal.lcl INTEGER R/O IntegerRange R/O (0 .. 0)
internal.sta2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.sec1 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.sec2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt4 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt5 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt6 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt7 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt8 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt9 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt10 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt12 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt13 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt14 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.maxChannels TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Beam over voltage)
faults.03 ALARM R/O AlarmFlagRange R/O (Beam under voltage)
faults.04 ALARM R/O AlarmFlagRange R/O (Beam over current)
faults.05 ALARM R/O AlarmFlagRange R/O (Beam under current)
faults.06 ALARM R/O AlarmFlagRange R/O (Beam during stdby)
faults.07 ALARM R/O AlarmFlagRange R/O (Body over current)
faults.08 ALARM R/O AlarmFlagRange R/O (External interlock)
faults.09 ALARM R/O AlarmFlagRange R/O (Heater over voltage)
faults.10 ALARM R/O AlarmFlagRange R/O (Heater under voltage)
faults.11 ALARM R/O AlarmFlagRange R/O (Heater over current)
faults.12 ALARM R/O AlarmFlagRange R/O (Heater under current)
faults.13 ALARM R/O AlarmFlagRange R/O (High voltage ARC)
faults.14 ALARM R/O AlarmFlagRange R/O (High voltage Interlock)
faults.15 ALARM R/O AlarmFlagRange R/O (Lost AC)
faults.16 ALARM R/O AlarmFlagRange R/O (Lost AC phase)
faults.17 ALARM R/O AlarmFlagRange R/O (15V under voltage)
faults.18 ALARM R/O AlarmFlagRange R/O (PS Blower)
faults.19 ALARM R/O AlarmFlagRange R/O (PS heatsink temp)
faults.20 ALARM R/O AlarmFlagRange R/O (Circulator over temp)
faults.21 ALARM R/O AlarmFlagRange R/O (Collector over temp)
faults.22 ALARM R/O AlarmFlagRange R/O (High reflected RF)
faults.23 ALARM R/O AlarmFlagRange R/O (High RF fault)
faults.24 ALARM R/O AlarmFlagRange R/O (Low RF fault)
faults.25 ALARM R/O AlarmFlagRange R/O (Klystron WG Arc 1)
faults.26 ALARM R/O AlarmFlagRange R/O (Channel changer)
faults.27 ALARM R/O AlarmFlagRange R/O (High outlet temp)
faults.28 ALARM R/O AlarmFlagRange R/O (Low airflow)
faults.29 ALARM R/O AlarmFlagRange R/O (High inlet humitidy)
faults.30 ALARM R/O AlarmFlagRange R/O (High outlet temp)
faults.31 ALARM R/O AlarmFlagRange R/O (High RF alarm)
faults.32 ALARM R/O AlarmFlagRange R/O (Low RF alarm)
faults.33 ALARM R/O AlarmFlagRange R/O (RF-Switch inhibit)
faults.34 ALARM R/O AlarmFlagRange R/O (Summary)
faults.35 ALARM R/O AlarmFlagRange R/O (Standby)
faults.36 ALARM R/O AlarmFlagRange R/O (Protection)