1.89 CPI-SLPA

This page describes the device driver and the device window for the CPI SuperLinear TWTA series with support for redundancy and up to 8 waveguide switches

The driver supports the following models:

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the amplifier.

parameter description
address The device address (decimal). The factory default is 48
powerDisplayMode Defines the display of gain or attenuation in the parameter section.
control.Point Defines the control via serial or ethernet interface.
redundancy Defines the redundancy mode
loRfOutAlarm The low output power alarm trip point.
hiRfOutAlarm The high output power alarm trip point.
loRfOutFault The low output power fault trip point.
hiRfOutFault The high output power fault trip point.
Serial Remember to set the line parameters for the serial interface. of the HPA is 9600,E,7,1 .
helixAdvWarning Sets the advanced helix current warning level. Not monitored if 0
logGainChanges Defines if gain changes should be written in the event log database. Can automatically be adjusted by logLevelEnabledId within Uplink Power Control
deviceComment An optional text entered here appears as an addition to the tooltip which is shown while the mouse is placed over a device icon in the GUI. The "\n" character sequence is translated into a newline character, splitting the text into multiple lines.

Ethernet Interface

The ODUs may be controlled through their Ethernet interface. The port number for this is 50000. Assuming the amplifier is set to an IP address 10.0.0.1, you have to configure a communication interface "10.0.0.1:50000" in the sat-nms VLC setup in order to make the VLC talk to the amplifier. Beside this, the amplifier must be configured to "Ethernet CIF" at it's web-interface.

Variables defined by this device driver

name type flags range