1.91 CPI-SRCU

This page describes the device driver and the device window for the CPI SRCU redundancy controller using CPI-STX protocol.

It was tested with 1:1 Redundancy Compact CMPA

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address The device address (decimal). The factory default is 65.
readBackDelay Delays the read back of a parameter actually set for at least the given delay time. This shall ensure that the device has processed the new parameter before it is read back. You should leave this parameter at it's default setting.
redundancy Defines the redundancy type.
switches Defines the number of installed switches 0-16.
deviceComment An optional text entered here appears as an addition to the tooltip which is shown while the mouse is placed over a device icon in the GUI. The "\n" character sequence is translated into a newline character, splitting the text into multiple lines.

Ethernet Interface

The ODUs may be controlled through their Ethernet interface. The port number for this is 50000. Assuming the amplifier is set to an IP address 10.0.0.1, you have to configure a communication interface "10.0.0.1:50000" int the sat-nms VLC setup in order to make the VLC talk to the amplifier. Beside this, the amplifier must be configured to "Ethernet CIF" at it's web-interface.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model CHOICE R/O EnumRange R/O (N/A 1:1 1:1-MAINTENANCE SWITCH 1:1-PHASE COMBINED 1:2 1:2-MAINTENANCE SWITCH 1:2-PHASE COMBINED)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
protection CHOICE EnumRange (MANUAL AUTO)
location CHOICE R/O EnumRange R/O (1 2)
position.01 CHOICE EnumRange (A B)
position.02 CHOICE EnumRange (A B)
position.03 CHOICE EnumRange (A B)
position.04 CHOICE EnumRange (A B)
internal.test INTEGER IntegerRange (0 .. 0)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Protection)
faults.11 ALARM R/O AlarmFlagRange R/O (HPA 1)
faults.12 ALARM R/O AlarmFlagRange R/O (HPA 2)
faults.13 ALARM R/O AlarmFlagRange R/O (HPA 3)
faults.21 ALARM R/O AlarmFlagRange R/O (Switch 1)
faults.22 ALARM R/O AlarmFlagRange R/O (Switch 2)
faults.23 ALARM R/O AlarmFlagRange R/O (Switch 3)
faults.24 ALARM R/O AlarmFlagRange R/O (Switch 4)