1.94 CPI-TWTA

This page describes the device driver and the device window for the CPI TWT amplifiers.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Amplifier.

parameter description
address The device address (decimal). The factory default is 48
checkLimits Turns the amplifier's built in power limit check off or on. When turned on, the amplifier generates a fault if the output power is outside the limits set below.
lowLimit The low output power limit.
highLimit The high output power limit.
Serial Remember to set the line parameters for the serial interface connected to the TWTA. The factory default of the HPA is 9600,E,7,1 .
helixAdvWarning Sets the advanced helix current warning level. Not monitored if 0
logGainChanges Defines if gain changes should be written in the event log database. Can automatically be adjusted by logLevelEnabledId within Uplink Power Control
deviceComment An optional text entered here appears as an addition to the tooltip which is shown while the mouse is placed over a device icon in the GUI. The "\n" character sequence is translated into a newline character, splitting the text into multiple lines.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.heatElapsed INTEGER R/O IntegerRange R/O (0 .. 100000)
info.beamElapsed INTEGER R/O IntegerRange R/O (0 .. 100000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.checkLimits CHOICE SAVE SETUP EnumRange (OFF ON)
config.lowLimit INTEGER SAVE SETUP IntegerRange (0 .. 1000)
config.highLimit INTEGER SAVE SETUP IntegerRange (0 .. 1000)
config.helixAdvWarning FLOAT SAVE SETUP DoubleRange (0.0 .. 0.0)
config.logGainChanges CHOICE SAVE SETUP EnumRange (ON OFF)
config.deviceComment TEXT SAVE SETUP StringRange
tx.on CHOICE EnumRange (OFF ON)
tx.beam CHOICE EnumRange (STANDBY ON)
tx.gain FLOAT DoubleRange (0.0 .. 25.0)
tx.attn FLOAT DoubleRange (0.0 .. 25.0)
reset TEXT NOPRESET StringRange
state TEXT R/O StringRange R/O
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 60.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.refPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.iHelix FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.uHelix FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
internal.dummy FLOAT R/O DoubleRange R/O (0 .. 0)
internal.summ INTEGER R/O IntegerRange R/O (0 .. 0)
internal.bsl INTEGER R/O IntegerRange R/O (0 .. 0)
internal.lcl INTEGER R/O IntegerRange R/O (0 .. 0)
internal.sta2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.sec1 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.sec2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt1 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt3 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flt4 INTEGER R/O IntegerRange R/O (0 .. 0)
faults.01 ALARM R/O AlarmFlagRange R/O (Summary)
faults.02 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.03 ALARM R/O AlarmFlagRange R/O (BB RAM)
faults.04 ALARM R/O AlarmFlagRange R/O (BUC unlock)
faults.05 ALARM R/O AlarmFlagRange R/O (High RF (alarm))
faults.06 ALARM R/O AlarmFlagRange R/O (Low RF (alarm))
faults.07 ALARM R/O AlarmFlagRange R/O (Power fail timeout)
faults.08 ALARM R/O AlarmFlagRange R/O (Helix over voltage)
faults.09 ALARM R/O AlarmFlagRange R/O (Helix under voltage)
faults.10 ALARM R/O AlarmFlagRange R/O (Helix avg. over current)
faults.11 ALARM R/O AlarmFlagRange R/O (Power supply arc trip)
faults.12 ALARM R/O AlarmFlagRange R/O (DC buss under voltage)
faults.13 ALARM R/O AlarmFlagRange R/O (Helix voltage in standby)
faults.14 ALARM R/O AlarmFlagRange R/O (Reflected RF)
faults.15 ALARM R/O AlarmFlagRange R/O (Cover interlock)
faults.16 ALARM R/O AlarmFlagRange R/O (TWT thermal interlock)
faults.17 ALARM R/O AlarmFlagRange R/O (High RF)
faults.18 ALARM R/O AlarmFlagRange R/O (Low RF)
faults.19 ALARM R/O AlarmFlagRange R/O (External interlock)
faults.20 ALARM R/O AlarmFlagRange R/O (Over temp)
faults.21 ALARM R/O AlarmFlagRange R/O (SSIPA over current)
faults.22 ALARM R/O AlarmFlagRange R/O (Helix advance warning)
faults.26 ALARM R/O AlarmFlagRange R/O (Standby)