1.180 ETI-ADH-NETCOM

This page describes the device driver and the device window for the Environmental Technology Inc. wave guide pressurizer / dehydrator ADH-NETCOM via SNMP

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.runTime FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.unitTemp TEXT R/O StringRange R/O
internal.unitPres TEXT R/O StringRange R/O
internal.unit TEXT R/O StringRange R/O
internal.temp INTEGER R/O IntegerRange R/O (0 .. 0)
internal.pressure FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
pressure INTEGER R/O IntegerRange R/O (0 .. 0)
pressure2 FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
temperature INTEGER R/O IntegerRange R/O (0 .. 0)
temperature2 INTEGER R/O IntegerRange R/O (0 .. 0)
absorptionUnit1 CHOICE R/O EnumRange R/O (IDLE IN USE REGENERATING)
absorptionCond1 CHOICE R/O EnumRange R/O (OK FULL DEAD UNKNOWN)
absorptionUnit2 CHOICE R/O EnumRange R/O (IDLE IN USE REGENERATING)
absorptionCond2 CHOICE R/O EnumRange R/O (OK FULL DEAD UNKNOWN)
dutyCycle INTEGER R/O IntegerRange R/O (0 .. 0)
dutyCycleTime FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (Low Pressure)
faults.02 ALARM R/O AlarmFlagRange R/O (High pressure)
faults.03 ALARM R/O AlarmFlagRange R/O (High duty cycle)
faults.04 ALARM R/O AlarmFlagRange R/O (High temperature)
faults.05 ALARM R/O AlarmFlagRange R/O (Low temperature)
faults.07 ALARM R/O AlarmFlagRange R/O (Canister 1 no heat)
faults.08 ALARM R/O AlarmFlagRange R/O (Canister 1 no cool)
faults.09 ALARM R/O AlarmFlagRange R/O (Canister 2 no heat)
faults.10 ALARM R/O AlarmFlagRange R/O (Canister 2 no cool)
faults.11 ALARM R/O AlarmFlagRange R/O (Unable to pressurize)
faults.12 ALARM R/O AlarmFlagRange R/O (Dew point alarm)
faults.15 ALARM R/O AlarmFlagRange R/O (Canister 1 thermistor)
faults.16 ALARM R/O AlarmFlagRange R/O (Canister 2 thermistor)
faults.17 ALARM R/O AlarmFlagRange R/O (Ambient thermistor)
faults.18 ALARM R/O AlarmFlagRange R/O (Overpressure)
faults.19 ALARM R/O AlarmFlagRange R/O (Bad cal. in EEPROM)
faults.20 ALARM R/O AlarmFlagRange R/O (Bad limits in EEPROM)
faults.21 ALARM R/O AlarmFlagRange R/O (Short cycling)
faults.22 ALARM R/O AlarmFlagRange R/O (Pump shutdown)