This page describes the device driver and the device window for the Environmental Technology Inc. wave guide pressurizer / dehydrator ADH-NETCOM via SNMP
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The operational parametersConfiguration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| info.runTime | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.unitTemp | TEXT | R/O | StringRange R/O |
| internal.unitPres | TEXT | R/O | StringRange R/O |
| internal.unit | TEXT | R/O | StringRange R/O |
| internal.temp | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.pressure | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| pressure | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| pressure2 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| temperature | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| temperature2 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| absorptionUnit1 | CHOICE | R/O | EnumRange R/O (IDLE IN USE REGENERATING) |
| absorptionCond1 | CHOICE | R/O | EnumRange R/O (OK FULL DEAD UNKNOWN) |
| absorptionUnit2 | CHOICE | R/O | EnumRange R/O (IDLE IN USE REGENERATING) |
| absorptionCond2 | CHOICE | R/O | EnumRange R/O (OK FULL DEAD UNKNOWN) |
| dutyCycle | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| dutyCycleTime | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Low Pressure) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (High pressure) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (High duty cycle) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (High temperature) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Low temperature) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Canister 1 no heat) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Canister 1 no cool) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Canister 2 no heat) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Canister 2 no cool) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Unable to pressurize) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (Dew point alarm) |
| faults.15 | ALARM | R/O | AlarmFlagRange R/O (Canister 1 thermistor) |
| faults.16 | ALARM | R/O | AlarmFlagRange R/O (Canister 2 thermistor) |
| faults.17 | ALARM | R/O | AlarmFlagRange R/O (Ambient thermistor) |
| faults.18 | ALARM | R/O | AlarmFlagRange R/O (Overpressure) |
| faults.19 | ALARM | R/O | AlarmFlagRange R/O (Bad cal. in EEPROM) |
| faults.20 | ALARM | R/O | AlarmFlagRange R/O (Bad limits in EEPROM) |
| faults.21 | ALARM | R/O | AlarmFlagRange R/O (Short cycling) |
| faults.22 | ALARM | R/O | AlarmFlagRange R/O (Pump shutdown) |