1.262 GDSatcom-RSC1200

This page describes the device driver and the device window for the GDSatcom LNA/LNB Redundancy Controller RSC-1200.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.

parameter description
currentWindow Current deviation which is acceptable without issue an alarm
latchedFaults Enable/Disable latched faults

Remarks

none

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.unitType CHOICE R/O EnumRange R/O (1:1 DUAL-1:1 1:2)
info.version TEXT R/O StringRange R/O
info.hasTrackingUnit TEXT R/O StringRange R/O
info.nominalCurrent.1 INTEGER R/O IntegerRange R/O (0 .. 1000)
info.nominalCurrent.2 INTEGER R/O IntegerRange R/O (0 .. 1000)
info.nominalCurrent.3 INTEGER R/O IntegerRange R/O (0 .. 1000)
info.nominalCurrent.4 INTEGER R/O IntegerRange R/O (0 .. 1000)
info.nominalCurrent.5 INTEGER R/O IntegerRange R/O (0 .. 1000)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.currentWindow CHOICE SETUP EnumRange (5% 10% 15% 20% 25%)
config.latchedFaults CHOICE SETUP EnumRange (ON OFF)
meas.current.1 INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.current.2 INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.current.3 INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.current.4 INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.current.5 INTEGER R/O IntegerRange R/O (0 .. 1000)
meas.voltage.1 FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
meas.voltage.2 FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
protection CHOICE EnumRange (MANUAL AUTO)
pol1 CHOICE R/O EnumRange R/O (MAIN STANDBY)
pol2 CHOICE R/O EnumRange R/O (MAIN STANDBY)
position CHOICE EnumRange (2-STBY 1-STBY 3-STBY A B)
position.1 CHOICE R/O EnumRange R/O (A B)
position.2 CHOICE R/O EnumRange R/O (A B)
priority CHOICE EnumRange (NONE POL1 POL2)
priority.2 CHOICE EnumRange (NONE UNIT1 UNIT2)
revert CHOICE EnumRange (ENABLED DISABLED)
resetFaults TEXT StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Unit Summary)
faults.02 ALARM R/O AlarmFlagRange R/O (Switch)
faults.03 ALARM R/O AlarmFlagRange R/O (PS Summary)
faults.04 ALARM R/O AlarmFlagRange R/O (Controller)
faults.06 ALARM R/O AlarmFlagRange R/O (Power Supply 1)
faults.07 ALARM R/O AlarmFlagRange R/O (Power Supply 2)
faults.08 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.09 ALARM R/O AlarmFlagRange R/O (Protection)
faults.11 ALARM R/O AlarmFlagRange R/O (Unit 1)
faults.12 ALARM R/O AlarmFlagRange R/O (Unit 2)
faults.13 ALARM R/O AlarmFlagRange R/O (Unit 3)
faults.14 ALARM R/O AlarmFlagRange R/O (Unit 4)
faults.15 ALARM R/O AlarmFlagRange R/O (Unit 5 (Track))
faults.16 ALARM R/O AlarmFlagRange R/O (Latched Unit Summary)
faults.17 ALARM R/O AlarmFlagRange R/O (Latched Switch)
faults.18 ALARM R/O AlarmFlagRange R/O (Latched PS Summary)
faults.19 ALARM R/O AlarmFlagRange R/O (Latched Controller)
internal.v1 TEXT R/O StringRange R/O
internal.v2 TEXT R/O StringRange R/O
internal.v3 TEXT R/O StringRange R/O