1.306 Infratec-PM

This page describes the device driver and the device window for the Infratec Power Module IP Switch series and was tested with : PM4-IP (4 ports), PM4-IPS (4 ports), PM8-IP (8 ports), PM8-IPS (8 ports), PM-IP GOTO (8 port rackmount), PM821-IP (8 ports).

The driver detects automatically the connected switch model and adjusts the number of available ports/outlets.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.uptime TEXT R/O StringRange R/O
info.sysName TEXT R/O StringRange R/O
config.pulseTime.01 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.pulseTime.02 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.pulseTime.03 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.pulseTime.04 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.pulseTime.05 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.pulseTime.06 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.pulseTime.07 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.pulseTime.08 INTEGER SETUP IntegerRange DIS (1 .. 36000)
config.name.01 TEXT SETUP StringRange DIS
config.name.02 TEXT SETUP StringRange DIS
config.name.03 TEXT SETUP StringRange DIS
config.name.04 TEXT SETUP StringRange DIS
config.name.05 TEXT SETUP StringRange DIS
config.name.06 TEXT SETUP StringRange DIS
config.name.07 TEXT SETUP StringRange DIS
config.name.08 TEXT SETUP StringRange DIS
name.01 TEXT R/O StringRange R/O DIS
name.02 TEXT R/O StringRange R/O DIS
name.03 TEXT R/O StringRange R/O DIS
name.04 TEXT R/O StringRange R/O DIS
name.05 TEXT R/O StringRange R/O DIS
name.06 TEXT R/O StringRange R/O DIS
name.07 TEXT R/O StringRange R/O DIS
name.08 TEXT R/O StringRange R/O DIS
state.01 CHOICE EnumRange DIS (ON OFF)
state.02 CHOICE EnumRange DIS (ON OFF)
state.03 CHOICE EnumRange DIS (ON OFF)
state.04 CHOICE EnumRange DIS (ON OFF)
state.05 CHOICE EnumRange DIS (ON OFF)
state.06 CHOICE EnumRange DIS (ON OFF)
state.07 CHOICE EnumRange DIS (ON OFF)
state.08 CHOICE EnumRange DIS (ON OFF)
pulse.01 TEXT NOPRESET StringRange DIS
pulse.02 TEXT NOPRESET StringRange DIS
pulse.03 TEXT NOPRESET StringRange DIS
pulse.04 TEXT NOPRESET StringRange DIS
pulse.05 TEXT NOPRESET StringRange DIS
pulse.06 TEXT NOPRESET StringRange DIS
pulse.07 TEXT NOPRESET StringRange DIS
pulse.08 TEXT NOPRESET StringRange DIS
internal.mib TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Model not supported)