This page describes the device driver and the device window for the NAIS-FP-Pulse-Output device. This device controls one single output port of a NAiS/Matsushita PLC. The output ist activated for a defined time everytime when an arbitrary position command arrives at the device.
Multiple devices of this type (and other members of the NAIS-FP-* -family) may refer to one single PLC device. To do so, configure these devices to share the serial interface of the PLC and set the configuration parameters of each particular switch/monitoring device to the same PLC (address) but to individual ports.
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- Commands the switch position. In a task-oriented user interface the NAIS-FP-Pulse-Output usually will be bound to a button which starts a pule at the output when pressed. Here, with the standard user interface for switchtes, you have to enter an arbitrary value to the 'position' text field.
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the alarm monitoring input at the PLC.
| parameter | description |
|---|---|
| address | The packet address of the PLC device. Usually this is "01". |
| port | The address of the output port to control. |
| pulse | The pulse duration (seconds). Be aware, that during the pulse time all polling of inputs at this PLC device is paused! |
| Serial | Remember to set the line parameters for the serial interface connected to the FPx PLC device. It requires the somewhat unusual setting 9600,O,8,1 . With multiple NAIS-FP-* -devices referring to the same PLC, the line speed needs to be setup only once. |
Remarks
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| config.port | TEXT | SAVE SETUP | StringRange |
| config.pulse | FLOAT | SAVE SETUP | DoubleRange (0.0 .. 2.0) |
| position | TEXT | NOPRESET | StringRange |