1.423 NDSatCom-RCU-RC11

This page describes the device driver and the device window for the ND-SatCom RCU redundancy controller via REST-API. It does not include the control of attached devices (like HPA or Modulator or Encoder) but is only responsible for the waveguide switch(es) and the redundancy settings and. Use the specific NDSatCom-TWTA-REST driver to access the attached devices via RCU ip address.

It supports only the following configuration:

For support of other configurations see other drivers mentioned in the documentation.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Controller.

parameter description
address The device IP address as set at the device's front panel followed by the API port which is set by default to 9876 from the vendor. E.g. 192.168.1.1:9876
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.
operationMode Select controllers switching mode SW-ONCE or SW-ALWAYS
deviceComment An optional text entered here appears as an addition to the tooltip which is shown while the mouse is placed over a device icon in the GUI. The "\n" character sequence is translated into a newline character, splitting the text into multiple lines.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.deviceName.01 TEXT R/O StringRange R/O
info.deviceName.02 TEXT R/O StringRange R/O
info.deviceName.03 TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.operationMode CHOICE SETUP EnumRange (SW-ONCE SW-ALWAYS)
protection CHOICE EnumRange (MANUAL AUTO BLOCKED)
switchFault BOOLEAN R/O BooleanRange R/O (true false)
location CHOICE EnumRange (1 2)
position CHOICE EnumRange (A B)
wgstat.1 HEX R/O HexRange R/O (0 .. 0)
wgcmd.1 HEX HexRange (0 .. 0)
internal.model TEXT R/O StringRange R/O
internal.dummy INTEGER R/O IntegerRange R/O (0 .. 0)
internal.once INTEGER R/O IntegerRange R/O (0 .. 0)
initialized TEXT R/O StringRange R/O
internal.loc TEXT R/O StringRange R/O
mGeneral TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (RCU Power Supply 1)
faults.02 ALARM R/O AlarmFlagRange R/O (RCU Power Supply 2)
faults.04 ALARM R/O AlarmFlagRange R/O (TX Chain 1)
faults.06 ALARM R/O AlarmFlagRange R/O (TX Chain 2)
faults.11 ALARM R/O AlarmFlagRange R/O (WG Switch 1)
faults.13 ALARM R/O AlarmFlagRange R/O (Unknown Version)