1.455 Newtec-MCX7000-BISS-Descr

This page describes the Newtec-MCX7000-BISS-Descr device driver and its device window. The Newtec-MCX7000-BISS-Descr device driver monitors and controls one BISS Descrambling instance configured in a Newtec MCX7000 Multi-carrier Satellite Gateway.

Multiple instances of the device may be configured in the sat-nms M&C to handle all BISS instances of the gateway. All devices referring to the same physical device must be configured at the same device thread / interface to ensure that SNMP requests to the device do not overlap.

The 'descrambler' configuration parameter is used to select which of the BISS instances in the Gateway this particular sat-nms device shall control. The software automatically evaluates the number of available instances at the gateway after software startup and sets the available choices of the 'input' configuration parameter accordingly. The RESET button on the Maintenance device screen page can be used to force a re-read of the descrambler list, e.g. if a new BISS instance has been added via the Newtec Web GUI.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.buriedId TEXT R/O StringRange R/O
config.descrambler CHOICE SAVE SETUP EnumRange (1)
scrambling CHOICE EnumRange (OFF ON)
bissMode CHOICE SAVE EnumRange (BISS-1 BISS-E)
bissEMode CHOICE EnumRange (BURIED INJECTED)
bissKey TEXT NOCOMPARE StringRange
bissInjectedId TEXT NOCOMPARE StringRange
reset TEXT NOPRESET StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (PAT CRC)
faults.02 ALARM R/O AlarmFlagRange R/O (PMT CRC)
faults.03 ALARM R/O AlarmFlagRange R/O (CAT CRC)
faults.04 ALARM R/O AlarmFlagRange R/O (SW Refused)
faults.05 ALARM R/O AlarmFlagRange R/O (Sig Overflow)