1.474 Novella-RU03

This page describes the device driver and the device window for Novella RU03 1:1 Redundancy Controller for Blockup- and downconverters via SNMP.

It was tested with SW version 97-6055/V1.0

The Novella RU04 covers units in 2:1 redundancy.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address The SNMP address specification for the device (details below).
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.
ctrlMode Defines the control mode REMOTE/LOCAL

SNMP address specification

The full address consists of the following fields: aaa.bbb.ccc.ddd:pppp read-community write-community

parameter description
aaa.bbb.ccc.ddd The IP address of the device in 'dotted quad' notation. This field is mandatory.
pppp The IP port number where the device accepts SNMP requests. The port number may be omitted, the driver uses the standard port 161 in this case.
read-community The SNMP read community name. This must match the read community expected by the device.
write-community The SNMP write community name. This must match the write community expected by the device. The write community name may be omitted, the driver uses the read community name for both, read and write in this case. If both community names are missing, the driver uses public as a default for read and write community string.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.name TEXT R/O StringRange R/O
info.siteDescription TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.description TEXT R/O StringRange R/O
config.ctrlMode CHOICE SETUP EnumRange (REMOTE LOCAL)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.deviceComment TEXT SAVE SETUP StringRange
position CHOICE R/O EnumRange R/O (A B)
location CHOICE EnumRange (1 2)
protection CHOICE EnumRange (AUTO MANUAL)
internal.f1 TEXT R/O StringRange R/O
internal.f2 TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Unit 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Unit 2)
faults.04 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.05 ALARM R/O AlarmFlagRange R/O (Protection)