1.477 Novotronik-GTA5200

This page describes the device driver and the device window for a Novotronik Multicoupler GT5200 series.

It was tested with the following models:

The driver is intended for monitoring only purpose without its own parameters page.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

The GTA5200 do not need any configuration parameters except the settings for the serial interface

parameter description
Serial Remember to set the line parameters for the serial interface connected to the device. The recommended line setting for the use with the sat-nms software is 9600,N,8,1 .
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.

Remote Control

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
info.swVersion TEXT R/O StringRange R/O
info.swDate TEXT R/O StringRange R/O
info.serialNo TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Voltage 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Voltage 2)
faults.03 ALARM R/O AlarmFlagRange R/O (Internal voltage)
faults.04 ALARM R/O AlarmFlagRange R/O (Internal System)
faults.05 ALARM R/O AlarmFlagRange R/O (Temperature)
faults.06 ALARM R/O AlarmFlagRange R/O (Amplifier 1)