1.480 Novotronik-GTS0752A

This page describes the device driver and the device window for a Novotronik 9x1 Switch GTS0752A.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

The GTS0752A do not need any configuration parameters except the settings for the serial interface

parameter description
Serial Remember to set the line parameters for the serial interface connected to the device. The recommended line setting for the use with the sat-nms software is 9600,N,8,1 .
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.

Remote Control

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
position CHOICE EnumRange (0 1 2 3 4 5 6 7 8 9)
position.01 CHOICE R/O EnumRange R/O (A B)
position.02 CHOICE R/O EnumRange R/O (A B)
position.03 CHOICE R/O EnumRange R/O (A B)
position.04 CHOICE R/O EnumRange R/O (A B)
position.05 CHOICE R/O EnumRange R/O (A B)
position.06 CHOICE R/O EnumRange R/O (A B)
position.07 CHOICE R/O EnumRange R/O (A B)
position.08 CHOICE R/O EnumRange R/O (A B)
position.09 CHOICE R/O EnumRange R/O (A B)
reset TEXT NOPRESET StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Summary)