1.545 Paradise-SSPA-2200AM

This page describes the device driver and the device window for the Paradise indoor SSPA amplifier 2200AM. It was tested with:

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the SSPA.

parameter description
address The device IP address and the SNMP community strings as set at the device's front panel.
powerDisplayMode Select if you want to see gain or attenuation
sysMode Allows to select the system configuration.
standbyMode Allows to select the standby mode in a redundant configuration.
powerSupplies Defines the number of power supplies to be monitored
hasRefPwrSensor Defines if the unit is equipped with a reflected power measurement sesnor.
gainMode Sets the units gain mode
hpaNumber Sets the HPA number

Communication protocol / Interface type

This device driver requires the SNMP protocol. Please remember to configure the ip settings (Main Menu - 2.Com Setup) and enable SNMP at the front panel

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.deviceType TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.sysMode CHOICE SETUP EnumRange (StandAlone 1:1 Dual-1:1 MaintenanceSwitch)
config.standbyMode CHOICE SETUP EnumRange (HotStandby ColdStandby)
config.powerSupplies CHOICE SAVE SETUP EnumRange (1 2)
config.hasRefPwrSensor CHOICE SAVE SETUP EnumRange (YES NO)
config.gainMode CHOICE SETUP EnumRange (MANUAL ALC VOLTAGE)
config.hpaNumber CHOICE SETUP EnumRange (HPA-1 HPA-2)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 20.0)
tx.attn FLOAT DoubleRange (0.0 .. 20.0)
tx.requestedLevel FLOAT DoubleRange (0.0 .. 80.0)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
tx.measuredLevel2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.refPwr FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.current FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.ps1Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.ps2Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.regulator1Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.regulator2Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.gate1Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.gate2Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temp FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
red.mode CHOICE EnumRange DIS (AUTO MANUAL)
red.switch CHOICE EnumRange DIS (STANDBY ONLINE)
position CHOICE EnumRange DIS (A B)
internal.fwd FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.ref FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.flt INTEGER R/O IntegerRange R/O (0 .. 0)
internal.on CHOICE R/O EnumRange R/O (OFF ON)
faults.01 ALARM R/O AlarmFlagRange R/O (Summary)
faults.02 ALARM R/O AlarmFlagRange R/O (High temp)
faults.03 ALARM R/O AlarmFlagRange R/O (Low DC current)
faults.04 ALARM R/O AlarmFlagRange R/O (Low DC regulator voltage)
faults.05 ALARM R/O AlarmFlagRange R/O (Ext Mute)
faults.06 ALARM R/O AlarmFlagRange R/O (Int Mute)
faults.07 ALARM R/O AlarmFlagRange R/O (Forward RF)
faults.08 ALARM R/O AlarmFlagRange R/O (Reflected RF)
faults.09 ALARM R/O AlarmFlagRange R/O (BUC)
faults.10 ALARM R/O AlarmFlagRange R/O (Spare)
faults.11 ALARM R/O AlarmFlagRange R/O (Auxiliary)
faults.12 ALARM R/O AlarmFlagRange R/O (Switch position 1)
faults.13 ALARM R/O AlarmFlagRange R/O (Switch position 2)
faults.26 ALARM R/O AlarmFlagRange R/O (Standby)