1.541 PTF-pft1220A

This page describes the device driver and the device window for the ptf 1226A AutoSwitch and Distribution from Precise Time and Frequency, Inc for MIB version 1 from 2003

Please Note: Switching a channel will also cause the system to enter manual mode and lock out the front panel. But there is no command to return to Automatic Mode therefore this driver does not support switching.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit as well as for initial setup.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
faults.01 ALARM R/O AlarmFlagRange R/O (A - Pulse Status)
faults.02 ALARM R/O AlarmFlagRange R/O (A - RF Status)
faults.03 ALARM R/O AlarmFlagRange R/O (B - Pulse Status)
faults.04 ALARM R/O AlarmFlagRange R/O (B - RF Status)
faults.05 ALARM R/O AlarmFlagRange R/O (Protection)
pulsePeriod INTEGER IntegerRange (100 .. 2000)
pulsePeriodRange INTEGER IntegerRange (1 .. 16)
maxRfPeriod INTEGER IntegerRange (20 .. 1280)
channel CHOICE R/O EnumRange R/O (A B)
protection CHOICE R/O EnumRange R/O (AUTO MANUAL)