1.551 RFDesign-RLS

This page describes the device driver and the device window for the RF Design RLC Series Splitter via SNMP.

The driver was tested with the following Models and SW Releases:

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the splitter.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.fwVersion TEXT R/O StringRange R/O
readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
position.1 CHOICE EnumRange (A B N/A)
position.2 CHOICE EnumRange (A B N/A)
gain.1 INTEGER IntegerRange (0 .. 25)
gain.2 INTEGER IntegerRange (0 .. 25)
eq.1 INTEGER IntegerRange (0 .. 9)
eq.2 INTEGER IntegerRange (0 .. 9)
meas.current.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.input.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.output.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.current.2 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.input.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.output.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
agc.1 CHOICE EnumRange (ON OFF)
agc.2 CHOICE EnumRange (ON OFF)
agc.refLevel.1 INTEGER IntegerRange (-40 .. 10)
agc.refLevel.2 INTEGER IntegerRange (-40 .. 10)
agc.hysteresis.1 INTEGER IntegerRange (1 .. 9)
agc.hysteresis.2 INTEGER IntegerRange (1 .. 9)
agc.timeWindow.1 INTEGER IntegerRange (1 .. 9)
agc.timeWindow.2 INTEGER IntegerRange (1 .. 9)
threshold.1 CHOICE EnumRange (ON OFF)
threshold.2 CHOICE EnumRange (ON OFF)
thresholdLevel.1 INTEGER IntegerRange (-40 .. 10)
thresholdLevel.2 INTEGER IntegerRange (-40 .. 10)
limiter.1 CHOICE EnumRange (ON OFF)
limiter.2 CHOICE EnumRange (ON OFF)
limiterLevel.1 INTEGER R/O IntegerRange R/O (-30 .. 10)
limiterLevel.2 INTEGER R/O IntegerRange R/O (-30 .. 10)
meas.lnbPower.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.lnbPower.2 INTEGER R/O IntegerRange R/O (0 .. 0)
lnb.power.1 CHOICE EnumRange (OFF 13V 15V 18V 13V+22kHz 18V+22kHz)
lnb.power.2 CHOICE EnumRange (OFF 13V 15V 18V 13V+22kHz 18V+22kHz)
lnb.refLevel.1 INTEGER IntegerRange (50 .. 350)
lnb.refLevel.2 INTEGER IntegerRange (50 .. 350)
lnb.hysteresis.1 INTEGER IntegerRange (10 .. 50)
lnb.hysteresis.2 INTEGER IntegerRange (10 .. 50)
faults.01 ALARM R/O AlarmFlagRange R/O (Power supply 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Power supply 2)
faults.03 ALARM R/O AlarmFlagRange R/O (Module 1 status)
faults.04 ALARM R/O AlarmFlagRange R/O (Module 2 status)
faults.05 ALARM R/O AlarmFlagRange R/O (Mod 1 RF pwr overflow)
faults.06 ALARM R/O AlarmFlagRange R/O (Mod 2 RF pwr overflow)
faults.07 ALARM R/O AlarmFlagRange R/O (Mod 1 Limiter)
faults.08 ALARM R/O AlarmFlagRange R/O (Mod 2 Limiter)
faults.09 ALARM R/O AlarmFlagRange R/O (Mod 1 Threshold)
faults.10 ALARM R/O AlarmFlagRange R/O (Mod 2 Threshold)
faults.11 ALARM R/O AlarmFlagRange R/O (Mod 1 AGC Lower limit)
faults.12 ALARM R/O AlarmFlagRange R/O (Mod 2 AGC Lower limit)
faults.13 ALARM R/O AlarmFlagRange R/O (Mod 1 AGC Upper limit)
faults.14 ALARM R/O AlarmFlagRange R/O (Mod 2 AGC Upper limit)
faults.15 ALARM R/O AlarmFlagRange R/O (Mod 1 AGC Lock)
faults.16 ALARM R/O AlarmFlagRange R/O (Mod 2 AGC Lock)
faults.17 ALARM R/O AlarmFlagRange R/O (Mod 1 Amp 1)
faults.18 ALARM R/O AlarmFlagRange R/O (Mod 1 Amp 2)
faults.19 ALARM R/O AlarmFlagRange R/O (Mod 2 Amp 1)
faults.20 ALARM R/O AlarmFlagRange R/O (Mod 2 Amp 2)
faults.21 ALARM R/O AlarmFlagRange R/O (Mod 1 LNB power)
faults.22 ALARM R/O AlarmFlagRange R/O (Mod 2 LNB power)
faults.23 ALARM R/O AlarmFlagRange R/O (Unit status)