1.650 Symmetricom-9611B

This page describes the device driver and the device window for the Symmetricom 2x12 Distribution Unit Type 9611B

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

The Symmetricom device needs some configuration parameters as well as the correct settings for the serial interface

parameter description
Serial Remember to set the line parameters for the serial interface connected to the device. The recommended line setting for the use with the sat-nms software is 115200,N,8,1 .
impedance Define if 50Ohm or 1kOhm impedance should be used.

Remote Control

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.impedance CHOICE SETUP EnumRange (50 Ohm 1000 Ohm)
info.model TEXT R/O StringRange R/O
info.versionMicro TEXT R/O StringRange R/O
info.versionFpga TEXT R/O StringRange R/O
input CHOICE EnumRange (1Hz to < 10Hz 10Hz to < 100Hz 100Hz to < 1kHz 1kHz to < 10kHz 10kHz to < 100kHz 100kHz and above Digital IRIG A Digital IRIG B Digital IRIG D Digital IRIG E Digital IRIG G Digital IRIG H AM IRIG - 100Hz carrier AM IRIG - 1kHz carrier AM IRIG - 10kHz carrier)
position CHOICE EnumRange (A B)
protection CHOICE EnumRange (AUTO USER)
internal.faultList TEXT R/O StringRange R/O
int.fault1 TEXT R/O StringRange R/O
int.fault2 TEXT R/O StringRange R/O
internal.position TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Input 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Input 2)
faults.03 ALARM R/O AlarmFlagRange R/O (Output 01)
faults.04 ALARM R/O AlarmFlagRange R/O (Output 02)
faults.05 ALARM R/O AlarmFlagRange R/O (Output 03)
faults.06 ALARM R/O AlarmFlagRange R/O (Output 04)
faults.07 ALARM R/O AlarmFlagRange R/O (Output 05)
faults.08 ALARM R/O AlarmFlagRange R/O (Output 06)
faults.09 ALARM R/O AlarmFlagRange R/O (Output 07)
faults.10 ALARM R/O AlarmFlagRange R/O (Output 08)
faults.11 ALARM R/O AlarmFlagRange R/O (Output 09)
faults.12 ALARM R/O AlarmFlagRange R/O (Output 10)
faults.13 ALARM R/O AlarmFlagRange R/O (Output 11)
faults.14 ALARM R/O AlarmFlagRange R/O (Output 12)
faults.15 ALARM R/O AlarmFlagRange R/O (Protection)