1.681 Terrasat-IBUC

This page describes the device driver and the device window for the Terrasat Ku-Band and C-Band L-Band Blockupconverter (IBUC).

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameter which must be set to make the software talk to the transceiver.

parameter description
address The device driver uses the terminal protocol to talk with the transceiver, hence there is no device addressing. Leave this field empty.
externalLED This enables or disables the LED on the chassis.
outputHighLimit Output high power level threshold
outputLowLimit Output low power level threshold
inputHighLimit Input high power level threshold
inputLowLimit Input low power level threshold
password This is the passwort which is used for login
txPowerupDelay Sets the delay for tx on at power up
txPowerupState If set to 'OFF', the IBUC starts with RF OFF when it is powered up. The 'LAST STATE' setting lets the transceiver return to the state when it was switched off
Serial Remember to set the line parameters for the serial interface connected to the transceiver. The transceiver either expects 9600,N,8,1 when set to factory settings.

Ethernet connection

If you want to use the TCP/IP M&C interface you have to configure the IP address of the IBUC first. Please refer to the Terrasat IBUC User Manual. The default Port is 23

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.externalLED CHOICE SETUP EnumRange (ON OFF)
config.outputHighLimit FLOAT SETUP DoubleRange (10.00 .. 60.00)
config.outputLowLimit FLOAT SETUP DoubleRange (10.00 .. 60.00)
config.inputHighLimit FLOAT SETUP DoubleRange (-60.00 .. -15.00)
config.inputLowLimit FLOAT SETUP DoubleRange (-60.00 .. -15.00)
config.password TEXT SAVE SETUP StringRange
config.txPowerupDelay INTEGER SETUP IntegerRange (0 .. 500)
config.txPowerupState CHOICE SETUP EnumRange (LAST STATE OFF)
config.highTempShutdown CHOICE SETUP EnumRange (ON OFF)
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.firmware TEXT R/O StringRange R/O
info.powerClass TEXT R/O StringRange R/O
info.ipAddress TEXT R/O StringRange R/O
info.loFrequency TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
rx.measuredLevel FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
tx.burstCount INTEGER IntegerRange (1 .. 16)
tx.burstThreshold FLOAT DoubleRange (0.0 .. 60.0)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 16.0)
tx.frequency INTEGER IntegerRange (0 .. 0)
tx.controlMode CHOICE EnumRange (Open Loop ALC AGC)
tx.gainTarget FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
tx.levelTarget FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
tx.gainControl FLOAT DoubleRange (0.00 .. 0.00)
tx.powerReadMode CHOICE EnumRange (CSM (cont.) Burst)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.measuredLevel FLOAT R/O DoubleRange R/O (0.000 .. 0.000)
meas.vdc FLOAT R/O DoubleRange R/O (0.0 .. 60.0)
meas.idc FLOAT R/O DoubleRange R/O (0.0 .. 12.5)
meas.temperature INTEGER R/O IntegerRange R/O (0 .. 0)
meas.pldroVoltage FLOAT R/O DoubleRange R/O (0.0 .. 10.0)
internal.faults HEX R/O HexRange R/O (0 .. 0)
internal.misc HEX R/O HexRange R/O (0 .. 0)
internal.login TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (AGC/ALC range)
faults.02 ALARM R/O AlarmFlagRange R/O (AGC/ALC not settled)
faults.03 ALARM R/O AlarmFlagRange R/O (Loss-of-lock)
faults.04 ALARM R/O AlarmFlagRange R/O (Output Level High)
faults.05 ALARM R/O AlarmFlagRange R/O (Output Level Low)
faults.06 ALARM R/O AlarmFlagRange R/O (Input Level High)
faults.07 ALARM R/O AlarmFlagRange R/O (Input Level Low)
faults.08 ALARM R/O AlarmFlagRange R/O (Temperature)
faults.09 ALARM R/O AlarmFlagRange R/O (Tx simulated)
faults.10 ALARM R/O AlarmFlagRange R/O (10MHz reference)
faults.11 ALARM R/O AlarmFlagRange R/O (VDC range)
faults.12 ALARM R/O AlarmFlagRange R/O (WG switch)
faults.13 ALARM R/O AlarmFlagRange R/O (IDC range)
faults.14 ALARM R/O AlarmFlagRange R/O (AGC/ALC target range)
faults.15 ALARM R/O AlarmFlagRange R/O (Wrong password)