This page describes the device driver and the device window for the Vertex LNA/LNV RSC-1200 1:2 redundancy controller.
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- The operational upconverter parameters
--- Meter readings
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| Serial | Remember to set the line parameters for the serial interface connected to the down-converter. It is recommended to operate the device at 19200,8N1 . |
Communication protocol / Interface type
This device driver requires the Vertex protocol. Please remember do define a address or use the factory default 0.
Installation
Before you can operate the down-converter with the satnms software, you must prepare the unit to match the interface parameters expected by the software.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.unitType | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| meas.current.1 | INTEGER | R/O | IntegerRange R/O (0 .. 1000) |
| meas.current.2 | INTEGER | R/O | IntegerRange R/O (0 .. 1000) |
| meas.current.3 | INTEGER | R/O | IntegerRange R/O (0 .. 1000) |
| meas.voltage.1 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| meas.voltage.2 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| protection | CHOICE | EnumRange (MANUAL AUTO) | |
| pol1 | CHOICE | EnumRange (MAIN STANDBY) | |
| pol2 | CHOICE | EnumRange (MAIN STANDBY) | |
| position | CHOICE | R/O | EnumRange R/O (3-STBY 1-STBY 2-STBY) |
| position.1 | CHOICE | EnumRange (A B) | |
| position.2 | CHOICE | EnumRange (A B) | |
| priority | CHOICE | EnumRange (NONE POL1 POL2) | |
| revert | CHOICE | EnumRange (ENABLED DISABLED) | |
| reset | TEXT | NOPRESET | StringRange |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Unit 1) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Unit 2) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Unit 3 (Spare)) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Power Supply 1) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Power Supply 2) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Controller) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Unit current) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Protection) |
| internal.unitType | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.state | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.fault1 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.fault2 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.pol1 | BOOLEAN | R/O | BooleanRange R/O (true false) |
| internal.pol2 | BOOLEAN | R/O | BooleanRange R/O (true false) |
| internal.08 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |