1.790 Walton-DDC-Deice

This page describes the device driver and the device window for the Walton DDC Deicing Control/Status Panel RT2L with up to 6 heaters.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Deicing Controller.

parameter description
address The address of the RT2L or 48 for RS232.
Serial Remember to set the line parameters for the serial interface connected to the UNITY e.g 9600,7,E,1 regarding the configuration of the DP-9

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.device TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
flags.local BOOLEAN R/O BooleanRange R/O (true false)
flags.wet BOOLEAN R/O BooleanRange R/O (true false)
flags.icy BOOLEAN R/O BooleanRange R/O (true false)
flags.feedheat BOOLEAN R/O BooleanRange R/O (true false)
heater.1 BOOLEAN R/O BooleanRange R/O (true false)
heater.2 BOOLEAN R/O BooleanRange R/O (true false)
heater.3 BOOLEAN R/O BooleanRange R/O (true false)
heater.4 BOOLEAN R/O BooleanRange R/O (true false)
heater.5 BOOLEAN R/O BooleanRange R/O (true false)
heater.6 BOOLEAN R/O BooleanRange R/O (true false)
system.call CHOICE EnumRange (ON OFF)
heater.call.1 CHOICE EnumRange (ON OFF)
heater.call.2 CHOICE EnumRange (ON OFF)
heater.call.3 CHOICE EnumRange (ON OFF)
heater.call.4 CHOICE EnumRange (ON OFF)
heater.call.5 CHOICE EnumRange (ON OFF)
heater.call.6 CHOICE EnumRange (ON OFF)
feed.dis CHOICE EnumRange (ON OFF)
heater.dis.1 CHOICE EnumRange (ON OFF)
heater.dis.2 CHOICE EnumRange (ON OFF)
heater.dis.3 CHOICE EnumRange (ON OFF)
heater.dis.4 CHOICE EnumRange (ON OFF)
heater.dis.5 CHOICE EnumRange (ON OFF)
heater.dis.6 CHOICE EnumRange (ON OFF)
internal.flags.1 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flags.2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flags.3 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flags.4 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flags.5 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flags.6 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flags.7 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.flags.8 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.byte1 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.byte2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.byte3 INTEGER R/O IntegerRange R/O (0 .. 0)
deice CHOICE EnumRange (OFF ON)
faults.01 ALARM R/O AlarmFlagRange R/O (Heater 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Heater 1 overtemp)
faults.03 ALARM R/O AlarmFlagRange R/O (Heater 2)
faults.04 ALARM R/O AlarmFlagRange R/O (Heater 2 overtemp)
faults.05 ALARM R/O AlarmFlagRange R/O (Heater 3)
faults.06 ALARM R/O AlarmFlagRange R/O (Heater 3 overtemp)
faults.07 ALARM R/O AlarmFlagRange R/O (Heater 4)
faults.08 ALARM R/O AlarmFlagRange R/O (Heater 4 overtemp)
faults.09 ALARM R/O AlarmFlagRange R/O (Heater 5)
faults.10 ALARM R/O AlarmFlagRange R/O (Heater 5 overtemp)
faults.11 ALARM R/O AlarmFlagRange R/O (Heater 6)
faults.12 ALARM R/O AlarmFlagRange R/O (Heater 6 overtemp)
faults.13 ALARM R/O AlarmFlagRange R/O (Local)
faults.14 ALARM R/O AlarmFlagRange R/O (Deice Standby)
faults.15 ALARM R/O AlarmFlagRange R/O (Fuel 20%)
faults.16 ALARM R/O AlarmFlagRange R/O (Fuel 50%)
faults.17 ALARM R/O AlarmFlagRange R/O (Feed)