1.750 Work-DualSSBU

This page describes the device driver and the device window for the Work Microwave Synthesized dual block upconverters SSBU.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the upconverter.

parameter description
address The device address (decimal) as set at the device's front panel.
Serial Remember to set the line parameters for the serial interface
powerDisplayMode Defines the display of gain or attenuation in the parameter section.
extMuteInput Defines to disable or enable the input for Hardware Mute (RF-Inhibit).
extRef Defines the reference source.
autoSave Store current parameters automatically in the instrument startup configuration.
bandSelect Defines the used frequency band.
loFreq.1 Defines the LO Frequency for Band 1.
loFreq.2 Defines the LO Frequency for Band 2.
accessMode Full Control: Enables changes on all tx parameters Blocked by RSCM: Disables changes on all tx parameters (readonly).
hasEqualizer Defines if the unit is equipped with an equalizer.

Remote Control

Default TCP Port= 50505

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.FrontBaseVersion TEXT R/O StringRange R/O
info.FrontDeviceVersion TEXT R/O StringRange R/O
info.InterfaceVersion TEXT R/O StringRange R/O
info.ReferenceVersion TEXT R/O StringRange R/O
info.SynthesizerVersion TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.extMuteInput CHOICE SETUP EnumRange (ENABLED DISABLED)
config.extRef CHOICE SETUP EnumRange (INTERNAL EXTERNAL AUTO)
config.autoSave CHOICE SETUP EnumRange (OFF ON)
config.bandSelect CHOICE SETUP EnumRange (BAND-1 BAND-2)
config.loFreq.1 FLOAT SETUP DoubleRange (0.000 .. 0.000)
config.loFreq.2 FLOAT SETUP DoubleRange (0.000 .. 0.000)
config.accessMode CHOICE SAVE SETUP EnumRange (FULL CONTROL BLOCKED BY RSCM)
config.hasEqualizer CHOICE SAVE SETUP EnumRange (NO YES)
tx.on CHOICE EnumRange (OFF ON)
tx.gain.1 FLOAT DoubleRange (0.0 .. 20.0)
tx.gain.2 FLOAT DoubleRange (0.0 .. 20.0)
tx.attn.1 FLOAT DoubleRange (0.0 .. 20.0)
tx.attn.2 FLOAT DoubleRange (0.0 .. 20.0)
tx.eq.1 FLOAT DoubleRange DIS (0.0 .. 8.0)
tx.eq.2 FLOAT DoubleRange DIS (0.0 .. 8.0)
meas.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.extRef BOOLEAN R/O BooleanRange R/O (true false)
meas.extMute BOOLEAN R/O BooleanRange R/O (true false)
reset TEXT StringRange
internal.sa0 INTEGER R/O IntegerRange R/O (0 .. 0)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (OCXO oven cold)
faults.03 ALARM R/O AlarmFlagRange R/O (Internal)
faults.04 ALARM R/O AlarmFlagRange R/O (Reference)
faults.05 ALARM R/O AlarmFlagRange R/O (Amplifier)
faults.06 ALARM R/O AlarmFlagRange R/O (MW output)
faults.07 ALARM R/O AlarmFlagRange R/O (Synthesizer)
faults.08 ALARM R/O AlarmFlagRange R/O (Block synthesizer)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)