This page describes the device driver and the device window for the Work Microwave Synthesized block downconverters SSBD.
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The receive parameters
--- The meter readings.
The redundancy switching parameters.
The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Downconverter.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| Serial | Remember to set the line parameters for the serial interface |
| powerDisplayMode | Defines the display of gain or attenuation in the parameter section. |
| extMuteInput | Defines to disable or enable the input for Hardware Mute (RF-Inhibit). |
| extRef | Defines the reference source. |
| autoSave | Store current parameters automatically in the instrument startup configuration. |
| loFreq | Defines the LO Frequency. |
| accessMode | Full Control: Enables changes on all rx parameters Blocked by RSCM: Disables changes on all rx parameters (readonly). |
| hasEqualizer | Defines if the unit is equipped with an equalizer. |
Remote Control
Default TCP Port= 50505
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.FrontBaseVersion | TEXT | R/O | StringRange R/O |
| info.FrontDeviceVersion | TEXT | R/O | StringRange R/O |
| info.InterfaceVersion | TEXT | R/O | StringRange R/O |
| info.ReferenceVersion | TEXT | R/O | StringRange R/O |
| info.SynthesizerVersion | TEXT | R/O | StringRange R/O |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| config.extMuteInput | CHOICE | SETUP | EnumRange (ENABLED DISABLED) |
| config.extRef | CHOICE | SETUP | EnumRange (INTERNAL EXTERNAL AUTO) |
| config.autoSave | CHOICE | SETUP | EnumRange (OFF ON) |
| config.bandSelect | CHOICE | SETUP | EnumRange (BAND-1 BAND-2) |
| config.loFreq | FLOAT | R/O | DoubleRange R/O (0.000 .. 0.000) |
| config.accessMode | CHOICE | SAVE SETUP | EnumRange (FULL CONTROL BLOCKED BY RSCM) |
| config.hasEqualizer | CHOICE | SAVE SETUP | EnumRange (NO YES) |
| rx.on | CHOICE | EnumRange (OFF ON) | |
| rx.gain | FLOAT | DoubleRange (0.0 .. 30.0) | |
| rx.attn | FLOAT | DoubleRange (0.0 .. 30.0) | |
| rx.eq | FLOAT | DoubleRange DIS (0.0 .. 8.0) | |
| meas.temperature | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.extRef | BOOLEAN | R/O | BooleanRange R/O (true false) |
| meas.extMute | BOOLEAN | R/O | BooleanRange R/O (true false) |
| reset | TEXT | StringRange | |
| internal.sa0 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (OCXO oven cold) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Internal) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Reference) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Amplifier) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (MW output) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Synthesizer) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Block synthesizer) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (TX Off) |