This page describes the device driver and the device window for the Work Microwave Calibration Source Type VSCSR
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The control parameters.
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| Serial | Remember to set the line parameters for the serial interface |
| extMuteInput | Defines to disable or enable the input for Hardware Mute (RF-Inhibit). |
| extRef | Defines the reference source. |
| autoSave | Store current parameters automatically in the instrument startup configuration. |
Remote Control
Default TCP Port= 50505
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.FrontBaseVersion | TEXT | R/O | StringRange R/O |
| info.FrontDeviceVersion | TEXT | R/O | StringRange R/O |
| info.InterfaceVersion | TEXT | R/O | StringRange R/O |
| info.ReferenceVersion | TEXT | R/O | StringRange R/O |
| info.SynthesizerVersion | TEXT | R/O | StringRange R/O |
| info.IfModuleVersion | TEXT | R/O | StringRange R/O |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.extRef | CHOICE | SETUP | EnumRange (INTERNAL EXTERNAL AUTO) |
| config.extMuteInput | CHOICE | SETUP | EnumRange (ENABLED DISABLED) |
| config.autoSave | CHOICE | SETUP | EnumRange (OFF ON) |
| tx.on | CHOICE | NOPRESET | EnumRange (OFF ON) |
| meas.extRef | BOOLEAN | R/O | BooleanRange R/O (true false) |
| meas.extMute | BOOLEAN | R/O | BooleanRange R/O (true false) |
| temp.controller | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| temp.refBoard | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| temp.synthesizer | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| reset | TEXT | NOPRESET | StringRange |
| internal.sa0 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (OCXO oven cold) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Internal) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Reference PLL) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Amplifier) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (MW output) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Synthesizer) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (TX Off) |