This page describes the device driver and the device window for the Acorde LNA/LNB Redundancy System Controller via SNMP.
Tested with the following 2:1 redundancy model:
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- The first parameter page displays the redundancy settings.
--- The second page shows the voltage and current measurement values.
--- The third page shows the voltage and current threshold values.
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.
Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.
| parameter | description |
|---|---|
| address | The SNMP address specification for the device (details below). |
| readBackDelay | Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances. |
| model | Defines the model redundancy type: 1:1 or 2:1 |
| remote | Sets the unit to remote or local access |
| hasTrackingLna | Defines if the unit is equipped with a separate tracking LNA. Set to NO by Default. |
| remote | Enable/Disable latched faults |
SNMP address specification
The full address consists of the following fields: aaa.bbb.ccc.ddd:pppp read-community write-community
| parameter | description |
|---|---|
| aaa.bbb.ccc.ddd | The IP address of the device in 'dotted quad' notation. This field is mandatory. |
| pppp | The IP port number where the device accepts SNMP requests. The port number may be omitted, the driver uses the standard port 161 in this case. |
| read-community | The SNMP read community name. This must match the read community expected by the device. |
| write-community | The SNMP write community name. This must match the write community expected by the device. The write community name may be omitted, the driver uses the read community name for both, read and write in this case. If both community names are missing, the driver uses public as a default for read and write community string. |
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.version | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.alias | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.model | CHOICE | SETUP | EnumRange (1:1 1:2) |
| config.remote | CHOICE | SETUP | EnumRange (REMOTE LOCAL) |
| config.hasTrackingLna | CHOICE | SAVE SETUP | EnumRange (NO YES) |
| meas.current.1 | INTEGER | R/O | IntegerRange R/O (0 .. 1000) |
| meas.current.2 | INTEGER | R/O | IntegerRange R/O (0 .. 1000) |
| meas.current.3 | INTEGER | R/O | IntegerRange R/O (0 .. 1000) |
| meas.current.4 | INTEGER | R/O | IntegerRange R/O (0 .. 1000) |
| meas.voltage.1 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.2 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.3 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.4 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltagePsu.1 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltagePsu.2 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| voltage.1.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| voltage.2.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| voltage.3.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| voltage.4.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| voltage.1.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| voltage.2.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| voltage.3.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| voltage.4.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.1.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.2.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.3.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.4.lowThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.1.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.2.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.3.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| current.4.highThd | FLOAT | DoubleRange (0.0 .. 0.0) | |
| protection | CHOICE | EnumRange (MANUAL AUTO) | |
| position | CHOICE | EnumRange (2-STBY 1-STBY 3-STBY A B) | |
| position.1 | CHOICE | R/O | EnumRange R/O (A B) |
| position.2 | CHOICE | R/O | EnumRange R/O (A B) |
| priority | CHOICE | EnumRange (NONE UNIT1 UNIT2) | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (User Memory) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Power Supply 1) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Power Supply 2) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Switch 1) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Switch 2) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Internal memory) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Protection) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Unit 1) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (Unit 2) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (Unit 3) |
| faults.14 | ALARM | R/O | AlarmFlagRange R/O (Unit 4) |
| faults.21 | ALARM | R/O | AlarmFlagRange R/O (Unit 1 Voltage) |
| faults.22 | ALARM | R/O | AlarmFlagRange R/O (Unit 2 Voltage) |
| faults.23 | ALARM | R/O | AlarmFlagRange R/O (Unit 3 Voltage) |
| faults.24 | ALARM | R/O | AlarmFlagRange R/O (Unit 4 Voltage) |
| faults.31 | ALARM | R/O | AlarmFlagRange R/O (Unit 1 Current) |
| faults.32 | ALARM | R/O | AlarmFlagRange R/O (Unit 2 Current) |
| faults.33 | ALARM | R/O | AlarmFlagRange R/O (Unit 3 Current) |
| faults.34 | ALARM | R/O | AlarmFlagRange R/O (Unit 4 Current) |