9.31 Advantech-SSPB-GCP

This page describes the device driver and the device window for the Advantech Wireless BUC via GCP (General Control panel). The SSPB itself does not provide a Ethernet interface. Therefore the driver talks with the GCP via SNMP. If more than one BUC is connected to the same Control panel the respective unit can be chosen from the device setup config.unit.

It was tested with non redundant ARMA type 160W HPAs

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
info.version TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.powerClass INTEGER R/O IntegerRange R/O (0 .. 0)
info.serialCtrl TEXT R/O StringRange R/O
info.shroudTemp FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.voltagePsu1Ctrl FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.voltagePsu2Ctrl FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.elapsedTime TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.unit CHOICE SAVE SETUP EnumRange (1 2 3 4 5 6)
config.redundancy CHOICE SAVE SETUP EnumRange (STANDALONE 1:1 2:1)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.accessMode CHOICE SETUP EnumRange (LOCAL REMOTE)
config.accessLock CHOICE SETUP EnumRange (UNLOCKED LOCKED)
config.extRef CHOICE SETUP EnumRange (INTERNAL EXTERNAL)
config.reference CHOICE SETUP EnumRange (MANUAL AUTO)
config.deviceComment TEXT SAVE SETUP StringRange
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 16.0)
tx.attn FLOAT DoubleRange (0.0 .. 16.0)
tx.alc CHOICE EnumRange (ON OFF)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.refPwr INTEGER R/O IntegerRange R/O (0 .. 0)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.hotspotTemp FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.current FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
protection CHOICE EnumRange (MANUAL AUTO)
location CHOICE R/O EnumRange R/O (STANDBY ONLINE)
position CHOICE EnumRange DIS (A B)
online TEXT NOPRESET StringRange DIS
onlineA TEXT NOPRESET StringRange DIS
onlineB TEXT NOPRESET StringRange DIS
reset TEXT NOPRESET StringRange
internal.min FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.max FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.on TEXT R/O StringRange R/O
internal.pout FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.pref FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (Units Positions)
faults.02 ALARM R/O AlarmFlagRange R/O (Transmit shutdown)
faults.03 ALARM R/O AlarmFlagRange R/O (No Communication)
faults.04 ALARM R/O AlarmFlagRange R/O (TX Fault)
faults.05 ALARM R/O AlarmFlagRange R/O (TX Alarm)
faults.06 ALARM R/O AlarmFlagRange R/O (Reflected Power)
faults.07 ALARM R/O AlarmFlagRange R/O (ALC High)
faults.08 ALARM R/O AlarmFlagRange R/O (ALC Low)
faults.09 ALARM R/O AlarmFlagRange R/O (TX Switch)
faults.10 ALARM R/O AlarmFlagRange R/O (TX SW Connected)
faults.11 ALARM R/O AlarmFlagRange R/O (Reference)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)