This page describes the device driver and the device window for the ASC Atlantic Satellite Corporation beacon receivers of series 3xx
You have to select the model name to adapts the frequency range. The driver was tested via Ethernet, but should also work on serial RS232 port.
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The operational parametersConfiguration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
| parameter | description |
|---|---|
| model | The beacon receiver model |
| Serial | Remember to set the line parameters for the serial interface (only if connected to serial port of beacon receiver and not to Ethernet) |
Ethernet interface
The Ethernet port of ASC3xx is realized with an internal Moxa N-Port server. Therefore you have to configure this N-Port server with the Moxa software tool to "TCP Server Mode" before you can connect the sat-nms MNC system.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.test | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.model | CHOICE | SAVE SETUP | EnumRange (unknown ASC302LE ASC350L ASC300L-D ASC300LW ASC300C ASC300D-70 ASC300Ku1 ASC300Ku2 ASC300KuET ASC300X) |
| voltage | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| frequency | FLOAT | DoubleRange (0.00 .. 0.00) | |
| attn | FLOAT | DoubleRange (0.0 .. 60.0) | |
| internal.v | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| internal.a | FLOAT | R/O | DoubleRange R/O (0.0 .. 60.0) |
| internal.f | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| internal.f1 | TEXT | R/O | StringRange R/O |
| internal.f2 | TEXT | R/O | StringRange R/O |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Lock alarm) |