9.144 Comtech-MBT5000

This page describes the Comtech-MBT5000 device driver and its device window. It controls 2 Blockupconverters or 2 Blockdownconverters via SNMP as well as mixed configuration of one Up- and one Downconverter.

It was tested with a 2xBUC model

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.model.1 TEXT R/O StringRange R/O
info.model.2 TEXT R/O StringRange R/O
info.range.1 TEXT R/O StringRange R/O
info.range.2 TEXT R/O StringRange R/O
info.ps12V.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.ps12V.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.ps7.8V FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.ps5V.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.ps5V.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.refVoltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.reference CHOICE R/O EnumRange R/O (N/A 5MHz 10MHz)
info.signal.on BOOLEAN R/O BooleanRange R/O (true false)
config.converterNumber CHOICE SAVE SETUP EnumRange (1 2)
config.hasRedundancy CHOICE SAVE SETUP EnumRange (YES NO)
config.converterOne CHOICE SAVE SETUP EnumRange (UPCONVERTER DOWNCONVERTER)
config.converterTwo CHOICE SAVE SETUP EnumRange (UPCONVERTER DOWNCONVERTER)
config.faultRecovery CHOICE SETUP EnumRange (MANUAL AUTO)
config.reference INTEGER SETUP IntegerRange (0 .. 255)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.deviceComment TEXT SAVE SETUP StringRange
meas.temperature.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.temperature.2 INTEGER R/O IntegerRange R/O (0 .. 0)
faultCode.1 TEXT R/O StringRange R/O
faultCode.2 TEXT R/O StringRange R/O
meas.level.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.level.2 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.2 INTEGER R/O IntegerRange R/O (0 .. 0)
tx.attn.1 FLOAT DoubleRange (0.00 .. 50.00)
tx.gain.1 FLOAT DoubleRange (0.00 .. 50.00)
tx.on.1 CHOICE EnumRange (OFF ON)
tx.frequency.1 FLOAT DoubleRange (0.000 .. 0.000)
tx.attn.2 FLOAT DoubleRange (0.00 .. 50.00)
tx.gain.2 FLOAT DoubleRange (0.00 .. 50.00)
tx.on.2 CHOICE EnumRange (OFF ON)
tx.frequency.2 FLOAT DoubleRange (0.000 .. 0.000)
rx.attn.1 FLOAT DoubleRange (0.00 .. 50.00)
rx.gain.1 FLOAT DoubleRange (0.00 .. 50.00)
rx.on.1 CHOICE EnumRange (OFF ON)
rx.attn.2 FLOAT DoubleRange (0.00 .. 50.00)
rx.gain.2 FLOAT DoubleRange (0.00 .. 50.00)
rx.on.2 CHOICE EnumRange (OFF ON)
protection CHOICE EnumRange DIS (AUTO MANUAL)
position CHOICE EnumRange DIS (A B)
tx.attnOffset.1 FLOAT DoubleRange DIS (-3.00 .. 3.00)
tx.attnOffset.2 FLOAT DoubleRange DIS (-3.00 .. 3.00)
reset TEXT NOPRESET StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Converter 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Converter 2)
faults.03 ALARM R/O AlarmFlagRange R/O (Base Unit)
faults.04 ALARM R/O AlarmFlagRange R/O (Low Power)
faults.05 ALARM R/O AlarmFlagRange R/O (Reference)
faults.06 ALARM R/O AlarmFlagRange R/O (Unit 1 Insert)
faults.07 ALARM R/O AlarmFlagRange R/O (Unit 2 Insert)
faults.08 ALARM R/O AlarmFlagRange R/O (LNA Current)
faults.09 ALARM R/O AlarmFlagRange R/O (PSU 1)
faults.10 ALARM R/O AlarmFlagRange R/O (PSU 2)
faults.11 ALARM R/O AlarmFlagRange R/O (Protection)
faults.26 ALARM R/O AlarmFlagRange R/O (RX/TX Off)