9.162 De-Icing-Multiplex

The De-Icing-Multiplex logical device controls up to eight antenna de-icing controllers to ensure that only one de-icing controller has it's heaters switched on at a time. The De-Icing-Multiplex device is used to reduce the maximum current draw by implementing this restriction.

The device requires that the de-icing controllers state a "I want to heat" flag with a BOOL parameter. The de-icing controls also must provide an OFF/ON CHOICE parameter to switch the heater actually off or on.

The De-Icing-Multiplex logical device implements a round-robin scheme to switch on the heaters (at those controllers which have the "request" flag set) one after the other after the "maxHeatingTime" timer runs down. The scheme preemptively releases the heating state, if a controller drops it's request flag.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to interconnect the redundancy switch with the devices it shall monitor and control.

parameter description
heatingRequestedId.* Defines the ID of the parameter which signals that this de-icing controller now requests heating. The parameter is expected to be a BOOL type.
heatingCommandId.* Defines the ID of the parameter which switches the heating of this controller actually ON/OFF. The parameter is expected to be a CHOICE type with the selection "OFF" and "ON".
maxHeatingTime Defines maximum time (minutes), the multiplexer switches on the heating at one particular controller. This is the round-robin time, after which the multiplexer proceeds to the next controller if more than one controller requests heating.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.heatingRequestedId.1 TEXT SAVE SETUP StringRange
config.heatingRequestedId.2 TEXT SAVE SETUP StringRange
config.heatingRequestedId.3 TEXT SAVE SETUP StringRange
config.heatingRequestedId.4 TEXT SAVE SETUP StringRange
config.heatingRequestedId.5 TEXT SAVE SETUP StringRange
config.heatingRequestedId.6 TEXT SAVE SETUP StringRange
config.heatingRequestedId.7 TEXT SAVE SETUP StringRange
config.heatingRequestedId.8 TEXT SAVE SETUP StringRange
config.heatingCommandId.1 TEXT SAVE SETUP StringRange
config.heatingCommandId.2 TEXT SAVE SETUP StringRange
config.heatingCommandId.3 TEXT SAVE SETUP StringRange
config.heatingCommandId.4 TEXT SAVE SETUP StringRange
config.heatingCommandId.5 TEXT SAVE SETUP StringRange
config.heatingCommandId.6 TEXT SAVE SETUP StringRange
config.heatingCommandId.7 TEXT SAVE SETUP StringRange
config.heatingCommandId.8 TEXT SAVE SETUP StringRange
config.maxHeatingTime INTEGER SAVE SETUP IntegerRange (1 .. 30)
heatingRequested.1 BOOLEAN R/O BooleanRange R/O (true false)
heatingRequested.2 BOOLEAN R/O BooleanRange R/O (true false)
heatingRequested.3 BOOLEAN R/O BooleanRange R/O (true false)
heatingRequested.4 BOOLEAN R/O BooleanRange R/O (true false)
heatingRequested.5 BOOLEAN R/O BooleanRange R/O (true false)
heatingRequested.6 BOOLEAN R/O BooleanRange R/O (true false)
heatingRequested.7 BOOLEAN R/O BooleanRange R/O (true false)
heatingRequested.8 BOOLEAN R/O BooleanRange R/O (true false)
heating.1 BOOLEAN R/O BooleanRange R/O (true false)
heating.2 BOOLEAN R/O BooleanRange R/O (true false)
heating.3 BOOLEAN R/O BooleanRange R/O (true false)
heating.4 BOOLEAN R/O BooleanRange R/O (true false)
heating.5 BOOLEAN R/O BooleanRange R/O (true false)
heating.6 BOOLEAN R/O BooleanRange R/O (true false)
heating.7 BOOLEAN R/O BooleanRange R/O (true false)
heating.8 BOOLEAN R/O BooleanRange R/O (true false)