This page describes the device driver and the device window for the EndRun 2x10 Frequency Distribution Unit FDC-3300.
The driver was tested with the following models:
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- Switch position.
--- The faults page.
--- The device info page.
--- The maintenance page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device and for proper operation.
| parameter | description |
|---|---|
| readBackDelay | Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances. |
| externalAlarm | Defines the usage of the two disable inputs and the disablemode behaviour of the FDC unit. If disablemode=y,y,off (or n,y,off or y,n,off) the chassis will turn off the reference input when it sees the disable input asserted and there is no good signal present on the other signal input. If disablemode=y,y,on (or n,y,on or y,n,on) then the chassis will switch between the primary and secondary inputs when the disable input is asserted. |
Remote Control
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.version | TEXT | R/O | StringRange R/O |
| info.versionFpga | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.externalAlarm | CHOICE | SETUP | EnumRange (Y-Y-ON Y-Y-OFF Y-N-ON Y-N-OFF N-Y-ON N-Y-OFF N-N) |
| position | CHOICE | R/O | EnumRange R/O (A B) |
| reset | TEXT | NOPRESET | StringRange |
| switchmode | CHOICE | EnumRange (A ONLY B ONLY A PRIMARY B PRIMARY) | |
| internal.extAlarm | TEXT | StringRange | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Input A) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Input B) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Output 1) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Output 2) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Output 3) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Output 4) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Output 5) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Output 6) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Output 7) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Output 8) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Output 9) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (Output 10) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (Power Supply A) |
| faults.14 | ALARM | R/O | AlarmFlagRange R/O (Power Supply B) |
| faults.15 | ALARM | R/O | AlarmFlagRange R/O (System oscillator) |
| faults.16 | ALARM | R/O | AlarmFlagRange R/O (Flash) |
| faults.17 | ALARM | R/O | AlarmFlagRange R/O (FPGA) |
| faults.18 | ALARM | R/O | AlarmFlagRange R/O (Disable External A) |
| faults.19 | ALARM | R/O | AlarmFlagRange R/O (Disable External B) |