9.268 Geosync-PS

This page describes the device driver and the device window for the Geosync Multi-Voltage Amplifier Power Supply System, through TCP Port 10001.

The driver was tested with the

and the following SW Releases:

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.

parameter description
address The address of the unit (Default = @)
iLowLimit.1 Defines the low current limit for Amplifier No. 1 in mA
iHighLimit.1 Defines the high current limit for Amplifier No. 1 in mA
iDeltaLimit.1 Defines the delta current limit for Amplifier No. 1 in mA
iLowLimit.2 Defines the low current limit for Amplifier No. 2 in mA
iHighLimit.2 Defines the high current limit for Amplifier No. 2 in mA
iDeltaLimit.2 Defines the delta current limit for Amplifier No. 2 in mA
iLowLimit.3 Defines the low current limit for Amplifier No. 3 in mA
iHighLimit.3 Defines the high current limit for Amplifier No. 3 in mA
iDeltaLimit.3 Defines the delta current limit for Amplifier No. 3 in mA
iLowLimit.4 Defines the low current limit for Amplifier No. 4 in mA
iHighLimit.4 Defines the high current limit for Amplifier No. 4 in mA
iDeltaLimit.4 Defines the delta current limit for Amplifier No. 4 in mA

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.iLowLimit.1 INTEGER SETUP IntegerRange (0 .. 1500)
config.iHighLimit.1 INTEGER SETUP IntegerRange (0 .. 1500)
config.iDeltaLimit.1 INTEGER SETUP IntegerRange (10 .. 1500)
config.iLowLimit.2 INTEGER SETUP IntegerRange (0 .. 1500)
config.iHighLimit.2 INTEGER SETUP IntegerRange (0 .. 1500)
config.iDeltaLimit.2 INTEGER SETUP IntegerRange (10 .. 1500)
config.iLowLimit.3 INTEGER SETUP IntegerRange (0 .. 1500)
config.iHighLimit.3 INTEGER SETUP IntegerRange (0 .. 1500)
config.iDeltaLimit.3 INTEGER SETUP IntegerRange (10 .. 1500)
config.iLowLimit.4 INTEGER SETUP IntegerRange (0 .. 1500)
config.iHighLimit.4 INTEGER SETUP IntegerRange (0 .. 1500)
config.iDeltaLimit.4 INTEGER SETUP IntegerRange (10 .. 1500)
config.voltage.1 CHOICE SETUP EnumRange (0V 12V 15V 20V)
config.voltage.2 CHOICE SETUP EnumRange (0V 12V 15V 20V)
config.voltage.3 CHOICE SETUP EnumRange (0V 12V 15V 20V)
config.voltage.4 CHOICE SETUP EnumRange (0V 12V 15V 20V)
meas.current.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.2 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.3 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.4 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.voltage.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.3 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.4 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.model TEXT StringRange
internal.dummy TEXT StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Amplifier 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Amplifier 2)
faults.03 ALARM R/O AlarmFlagRange R/O (Amplifier 3)
faults.04 ALARM R/O AlarmFlagRange R/O (Amplifier 4)
faults.05 ALARM R/O AlarmFlagRange R/O (Amplifier Delta 1)
faults.06 ALARM R/O AlarmFlagRange R/O (Amplifier Delta 2)
faults.07 ALARM R/O AlarmFlagRange R/O (Amplifier Delta 3)
faults.08 ALARM R/O AlarmFlagRange R/O (Amplifier Delta 4)
faults.09 ALARM R/O AlarmFlagRange R/O (PSU 1 24V)
faults.10 ALARM R/O AlarmFlagRange R/O (PSU 2 24V)
faults.11 ALARM R/O AlarmFlagRange R/O (PSU 1 6V)
faults.12 ALARM R/O AlarmFlagRange R/O (PSU 2 6V)
faults.13 ALARM R/O AlarmFlagRange R/O (Internal VDC Control)
faults.14 ALARM R/O AlarmFlagRange R/O (Remote Access)