9.290 Hiltron-HCS-SSPA

This page describes the device driver and the device window for the Hiltron-HCS-SSPA device. This device monitors the state a SSPA connected via HCS3 frame. To manage multiple modules of this kind in one HCS3 controller you have to configure multiple instances of the driver, all using the same IP address.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to integrate the device into the VLC/M&C.

Remarks

If you change the 'module' configuration parameter, the module identification at the info page is not updated automatically. This happens with the next restart of the software. To force an update of these readings, set the device OUT-OF-SERVICE and then OPERATIONAL again.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.name TEXT R/O StringRange R/O
info.slot TEXT R/O StringRange R/O
info.card TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.module CHOICE SAVE SETUP EnumRange (1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18)
tx.on CHOICE EnumRange (ON OFF)
tx.gain FLOAT DoubleRange (0.0 .. 20.0)
tx.attn FLOAT DoubleRange (0.0 .. 20.0)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.fwdPwr FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temp INTEGER R/O IntegerRange R/O (0 .. 0)
meas.refPwr INTEGER R/O IntegerRange R/O (0 .. 0)
state TEXT R/O StringRange R/O
meas.voltage FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
meas.current FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.level FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (Summary alarm)
faults.02 ALARM R/O AlarmFlagRange R/O (Summary fail)
faults.03 ALARM R/O AlarmFlagRange R/O (External interlock)
faults.04 ALARM R/O AlarmFlagRange R/O (Internal interlock)
faults.05 ALARM R/O AlarmFlagRange R/O (RF Alarm)
faults.07 ALARM R/O AlarmFlagRange R/O (RF FAIL)
faults.09 ALARM R/O AlarmFlagRange R/O (BUC alarm)
faults.10 ALARM R/O AlarmFlagRange R/O (BUC fail)
faults.11 ALARM R/O AlarmFlagRange R/O (Temperature alarm)
faults.12 ALARM R/O AlarmFlagRange R/O (Temperature fail)
faults.13 ALARM R/O AlarmFlagRange R/O (High reflected RF)
faults.14 ALARM R/O AlarmFlagRange R/O (Intern reflected RF)
faults.15 ALARM R/O AlarmFlagRange R/O (HPA Communication)