This page describes the monitoring only device driver and the device window for the Hitec antenna front panel including deicing parameters, temperatures and different summary alarms. ACU parameters are not included as they are implemented directly in Hitec-HACU-01 device
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The antenna front panel main page
--- The operational parameters
--- The faults page.
--- The device info page.
--- The maintenance page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| readBackDelay | Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances. |
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| deice.status | CHOICE | EnumRange (OFF AUTOMATIC) | |
| deice.auto | CHOICE | EnumRange (OFF ON) | |
| deice.remote | BOOLEAN | R/O | BooleanRange R/O (true false) |
| deice.requested | BOOLEAN | R/O | BooleanRange R/O (true false) |
| feedblower.status | CHOICE | R/O | EnumRange R/O (OFF ON) |
| state.rain | BOOLEAN | R/O | BooleanRange R/O (true false) |
| deice.a | BOOLEAN | R/O | BooleanRange R/O (true false) |
| deice.b | BOOLEAN | R/O | BooleanRange R/O (true false) |
| deice.c | BOOLEAN | R/O | BooleanRange R/O (true false) |
| deice.d | BOOLEAN | R/O | BooleanRange R/O (true false) |
| deice.subref | BOOLEAN | R/O | BooleanRange R/O (true false) |
| temp.outsite | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| temp.aped | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| temp.ahub | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| temp.driveCabinet | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| temp.powerCabinet | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| humidity.outsite | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| humidity.aped | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| humidity.ahub | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Emergency stop) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Drive Summary) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (General Summary) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (RF Summary) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Climatic Summary) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Deicing Summary) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Access Summary) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Final Limit) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Rain blower fuse) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Rain blower) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (Deicing fuse) |
| faults.14 | ALARM | R/O | AlarmFlagRange R/O (Deicing surge protect) |
| faults.20 | ALARM | R/O | AlarmFlagRange R/O (Deicing off) |
| faults.21 | ALARM | R/O | AlarmFlagRange R/O (Remote Access) |
| faults.22 | ALARM | R/O | AlarmFlagRange R/O (APED 1 Fuse) |
| faults.23 | ALARM | R/O | AlarmFlagRange R/O (APED 2 Fuse) |
| internal.r | INTEGER | R/O | IntegerRange R/O (0 .. 0) |