9.360 Mitec-TX

This page describes the device driver and the device window for a Mitec TX Uplink Controller/SSPA Switching Unit.

The driver supports the 1:1 redundancy model and is prepared to support 2:1 redundancy.
It is tested with two Advantech SSPAs. Each SSPA is handled as an individual device so therefore 2 or 3 instances of the Mitec-TX have to be set up.

Note: For proper operation the gain low and high Limits for individual SSPA have to be set

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the amplifier.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.name TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.bucVersion TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (ON OFF)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.minGain FLOAT SAVE SETUP DoubleRange (0.0 .. 0.0)
config.maxGain FLOAT SAVE SETUP DoubleRange (0.0 .. 0.0)
config.redundancy CHOICE SAVE SETUP EnumRange (1:1 2:1)
config.bucNumber CHOICE SAVE SETUP EnumRange (BUC-1 BUC-2 BUC-3)
config.deviceComment TEXT R/O StringRange R/O
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 0.0)
tx.attn FLOAT DoubleRange (0.0 .. 0.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.vdc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
protection CHOICE EnumRange (MANUAL AUTO)
location CHOICE EnumRange (STANDBY ONLINE)
position CHOICE R/O EnumRange R/O (A B)
position.1 CHOICE R/O EnumRange R/O (A B)
position.2 CHOICE R/O EnumRange R/O DIS (A B)
reset TEXT NOPRESET StringRange
internal.forwardPower TEXT R/O StringRange R/O
internal.on TEXT R/O StringRange R/O
internal.pout FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.deltaGain FLOAT DoubleRange (0.0 .. 0.0)
internal.attn FLOAT DoubleRange (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (Summary)
faults.02 ALARM R/O AlarmFlagRange R/O (Out of lock)
faults.03 ALARM R/O AlarmFlagRange R/O (Temperature)
faults.04 ALARM R/O AlarmFlagRange R/O (Voltage)
faults.05 ALARM R/O AlarmFlagRange R/O (Over Power)
faults.06 ALARM R/O AlarmFlagRange R/O (Latched 1)
faults.07 ALARM R/O AlarmFlagRange R/O (Latched 2)
faults.08 ALARM R/O AlarmFlagRange R/O (Latched 3)
faults.09 ALARM R/O AlarmFlagRange R/O (Switch 1)
faults.10 ALARM R/O AlarmFlagRange R/O (Switch 2)
faults.25 ALARM R/O AlarmFlagRange R/O (Protection)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)