This page describes the device driver and the device window for the Miteq down-converters 9900 series via Miteq-MOD95 e.g.:
It was tested with Ku Band version with SW: Rev 1.121
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- The operational parameters
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Downconverter.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| readBackDelay | Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances. |
| ifFrequency | Sets if frequency between 70 MHz and 140 MHz. |
| gainRange | Adjust the gain range to match the respective downconverter. |
| powerDisplayMode | Defines the display of gain or attenuation in the parameter section. |
| deviceComment | An optional text entered here appears as an addition to the tooltip which is shown while the mouse is placed over a device icon in the GUI. The "\n" character sequence is translated into a newline character, splitting the text into multiple lines. |
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.name | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| info.unitId | TEXT | R/O | StringRange R/O |
| info.reference | TEXT | R/O | StringRange R/O |
| info.signal.on | CHOICE | R/O | EnumRange R/O (ON OFF) |
| info.voltage.1 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| info.voltage.2 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| info.voltage.3 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| info.voltage.4 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.ifFrequency | CHOICE | SETUP | EnumRange (70 MHz 140 MHz) |
| config.gainRange | INTEGER | SAVE SETUP | IntegerRange (0 .. 0) |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| config.deviceComment | TEXT | SAVE SETUP | StringRange |
| rx.on | CHOICE | EnumRange (ON OFF) | |
| rx.frequency | FLOAT | DoubleRange (0.000 .. 0.000) | |
| rx.attn | FLOAT | DoubleRange (0.0 .. 30.0) | |
| rx.gain | FLOAT | DoubleRange (0.0 .. 30.0) | |
| internal.gain | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Test) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Logged) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (LO) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (PSU) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (LO Level) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Amp Current) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (External) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Temperature) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Module Comms) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (RX Off) |