This page describes the device driver and the device window for the Miteq Test Loop Translator with synthesizeable LO frequency DN9700 series via Miteq-MOD95.
It was tested with:
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- The transmit parameters
--- The meter readings
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| powerDisplayMode | Defines the display of gain or attenuation in the parameter section. |
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.name | TEXT | R/O | StringRange R/O |
| info.version | TEXT | R/O | StringRange R/O |
| info.ifFrequency | CHOICE | R/O | EnumRange R/O (70MHz 140MHz) |
| info.voltageP.15.3 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| info.voltageA.5.3 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| info.voltageB.5.3 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| info.voltageN.15.3 | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| info.extRef | CHOICE | R/O | EnumRange R/O (INTERNAL EXTERNAL) |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| tx.on | CHOICE | EnumRange (OFF ON) | |
| tx.gain | INTEGER | IntegerRange (0 .. 30) | |
| tx.attn | INTEGER | IntegerRange (0 .. 30) | |
| lo.frequency | FLOAT | DoubleRange (0.000000 .. 0.000000) | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Test) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Logged alarm) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (LO) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Power Supply) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Redundancy Bus) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Redundancy switch) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (External) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (TX OFF) |