9.372 Miteq-Upconverter-9900-SNMP

This page describes the device driver and the device window for the Miteq up-converters 9900 series via SNMP

It detects the frequency range and sets it's range accordingly.

It was tested with a C-Band upconverter

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Upconverter.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.name TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.xilinx TEXT R/O StringRange R/O
info.unitId TEXT R/O StringRange R/O
info.bands INTEGER R/O IntegerRange R/O (0 .. 0)
info.loFreq INTEGER R/O IntegerRange R/O (0 .. 0)
info.lowFreqEdge INTEGER R/O IntegerRange R/O (0 .. 0)
info.highFreqEdge INTEGER R/O IntegerRange R/O (0 .. 0)
info.signal.on CHOICE R/O EnumRange R/O (ON OFF)
info.voltage.1 FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
info.voltage.2 FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
info.voltage.3 FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
info.voltage.4 FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.gainRange INTEGER SAVE SETUP IntegerRange (0 .. 0)
config.ifFrequency CHOICE SETUP EnumRange (70 MHz 140 MHz)
config.impedance CHOICE SETUP EnumRange (50 Ohm 75 Ohm)
config.band INTEGER SETUP IntegerRange (1 .. 16)
config.frequencyDac INTEGER SETUP IntegerRange (0 .. 4095)
config.deviceComment TEXT SAVE SETUP StringRange
tx.on CHOICE EnumRange (ON OFF)
tx.frequency FLOAT DoubleRange (0.000 .. 0.000)
tx.attn FLOAT DoubleRange (0.0 .. 30.0)
tx.gain FLOAT DoubleRange (0.0 .. 30.0)
tx.slope FLOAT DoubleRange (0.0 .. 30.0)
internal.gain INTEGER R/O IntegerRange R/O (0 .. 0)
faults.01 ALARM R/O AlarmFlagRange R/O (Test)
faults.02 ALARM R/O AlarmFlagRange R/O (Logged)
faults.03 ALARM R/O AlarmFlagRange R/O (LO)
faults.04 ALARM R/O AlarmFlagRange R/O (PSU)
faults.05 ALARM R/O AlarmFlagRange R/O (LO Level)
faults.06 ALARM R/O AlarmFlagRange R/O (Amp Current)
faults.07 ALARM R/O AlarmFlagRange R/O (External)
faults.08 ALARM R/O AlarmFlagRange R/O (Temperature)
faults.09 ALARM R/O AlarmFlagRange R/O (Module Comms)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)