9.458 Newtec-MCX7000-IPIN

This page describes the Newtec-MCX7000-IPIN device driver and its device window. The Newtec-MCX7000-ASIOUT device driver monitors and controls one IP input configured in a Newtec MCX7000 Multi-carrier Satellite Gateway.

Multiple instances of the device may be configured in the sat-nms M&C to handle all IP inputs of the gateway. All devices referring to the same physical device must be configured at the same device thread / interface to ensure that SNMP requests to the device do not overlap.

The 'input' configuration parameter is used to select which of the IP inputs in the Gateway this particular sat-nms device shall control. The software automatically evaluates the number of available IP inputs at the gateway after software startup and sets the available choices of the 'input' configuration parameter accordingly. The RESET button on the Maintenance device screen page can be used to force a re-read of the input list, e.g. if a new IP input has been added via the Newtec Web GUI.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
config.input CHOICE SAVE SETUP EnumRange (1)
internal.enable TEXT R/O StringRange R/O
inputEnable CHOICE EnumRange (ON OFF)
inputProtocol CHOICE EnumRange (UDP RTP RTP-FEC)
srcPort INTEGER IntegerRange (1 .. 65535)
bufferDuration INTEGER IntegerRange (10 .. 1000)
bufferDurationMax INTEGER IntegerRange (10 .. 1000)
rateType CHOICE EnumRange (PCR USER)
bitrate FLOAT DoubleRange (0.000000 .. 0.000000)
pcrpid INTEGER IntegerRange (0 .. 8191)
loopType CHOICE EnumRange (NONE DVB NTC)
bindMode CHOICE EnumRange (UNBOUND MULTICAST)
autoPcr CHOICE EnumRange (ON OFF)
recoveryMode CHOICE EnumRange (SOURCE SEAMLESS)
recoveryWindow INTEGER IntegerRange (50 .. 900)
operationState TEXT R/O StringRange R/O
meas.bitrate FLOAT R/O DoubleRange R/O (0.000000 .. 0.000000)
meas.offset FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
meas.bufferDuration INTEGER R/O IntegerRange R/O (0 .. 0)
meas.bufferDurationMin INTEGER R/O IntegerRange R/O (0 .. 0)
meas.bufferDurationMax INTEGER R/O IntegerRange R/O (0 .. 0)
meas.srcAddress TEXT R/O StringRange R/O
meas.srcPort TEXT R/O StringRange R/O
meas.fec TEXT R/O StringRange R/O
meas.packetsLost INTEGER R/O IntegerRange R/O (0 .. 0)
meas.packetsCorr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.pcrpid INTEGER R/O IntegerRange R/O (0 .. 0)
meas.packetsNull INTEGER R/O IntegerRange R/O (0 .. 0)
flags.ip BOOLEAN R/O BooleanRange R/O (true false)
reset TEXT NOPRESET StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Input data)
faults.02 ALARM R/O AlarmFlagRange R/O (Buffer underflow)
faults.03 ALARM R/O AlarmFlagRange R/O (Buffer overflow)
faults.04 ALARM R/O AlarmFlagRange R/O (RTP Sync)
faults.05 ALARM R/O AlarmFlagRange R/O (Buffer Delay)
faults.06 ALARM R/O AlarmFlagRange R/O (Redundancy)