This page describes the device driver and the device window for the Newtec NTC 2142 Up and Downconverter with RCMP Protocol Version 1.0
It was tested with:
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- The receive parameters
--- The transmit parameters
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| reference | Defines if internal or external reference is used. |
| autoStore | Switching this to YES makes the driver automatically save the device configuration into it's flash memory after every change. NO disables automatic saving, you may use the 'SAVE BOOT CONFIG' button in the sat-nms GUI to save the actual configuration explicitly. |
| deviceComment | An optional text entered here appears as an addition to the tooltip which is shown while the mouse is placed over a device icon in the GUI. The "\n" character sequence is translated into a newline character, splitting the text into multiple lines. |
| powerDisplayMode | Defines the display of gain or attenuation in the parameter section. |
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.productId | TEXT | R/O | StringRange R/O |
| info.hwId | TEXT | R/O | StringRange R/O |
| info.hwVersion | TEXT | R/O | StringRange R/O |
| info.swVersion | TEXT | R/O | StringRange R/O |
| info.temperature | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| config.reference | CHOICE | SETUP | EnumRange (INTERNAL EXTERNAL) |
| config.autoStore | CHOICE | SAVE SETUP | EnumRange (ON OFF) |
| config.deviceComment | TEXT | SAVE SETUP | StringRange |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| internal.save | BOOLEAN | R/O | BooleanRange R/O (true false) |
| meas.if.rxLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.if.txLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.txLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.int.txLevel | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| tx.if.frequency | CHOICE | EnumRange (70 MHz 140 MHz) | |
| tx.polarity | CHOICE | EnumRange (DIRECT INVERTED) | |
| tx.inputGain | FLOAT | DoubleRange (-20.0 .. 30.0) | |
| tx.inputAttn | FLOAT | DoubleRange (-30.0 .. 20.0) | |
| tx.inputBw | CHOICE | EnumRange (40 MHz 80 MHz) | |
| tx.gain | FLOAT | DoubleRange (-23.0 .. 22.0) | |
| tx.attn | FLOAT | DoubleRange (-22.0 .. 23.0) | |
| tx.frequency | FLOAT | DoubleRange (0.000000 .. 0.000000) | |
| tx.int.on | CHOICE | EnumRange (OFF ON) | |
| rx.frequency | FLOAT | DoubleRange (950.000000 .. 2150.000000) | |
| rx.gain | FLOAT | DoubleRange (0.0 .. 50.0) | |
| rx.attn | FLOAT | DoubleRange (0.0 .. 50.0) | |
| rx.if.frequency | CHOICE | EnumRange (70 MHz 140 MHz) | |
| rx.polarity | CHOICE | EnumRange (DIRECT INVERTED) | |
| rx.if.on | CHOICE | EnumRange (ON OFF) | |
| rx.outputBw | CHOICE | EnumRange (40 MHz 80 MHz) | |
| reset | TEXT | NOPRESET | StringRange |
| clear | TEXT | NOPRESET | StringRange |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Reset) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Power on self test) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Incompatibilty) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (General) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Interface) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Reference clock) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Temperature) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (PS Voltage) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (LO 1 Upconverter) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (LO 1 Downconverter) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (LO 2 Upconverter) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (LO 2 Downconverter) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (Input overload) |
| faults.15 | ALARM | R/O | AlarmFlagRange R/O (Output overload) |
| faults.16 | ALARM | R/O | AlarmFlagRange R/O (Output underload) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (M&C module) |
| faults.27 | ALARM | R/O | AlarmFlagRange R/O (Upconverter) |
| faults.28 | ALARM | R/O | AlarmFlagRange R/O (Downconverter) |
| faults.31 | ALARM | R/O | AlarmFlagRange R/O (Architecture) |