9.482 Novotronik-GTS5022

This page describes the device driver and the device window for a Novotronik 4x1 Switch from type GTS5022.

The switch has 4 ports, possible position setting values are 0,1,2...4, position 0 means that no input is connected to the output and all ports are terminated with proper matching impedances.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

The GTS5022 do not need any configuration parameters except the settings for the serial interface

Remote control

Remote control is available via TCP Port 9998 with the "Terminal-LF-LFCR" ASCII protocol. Remember to switch to Remote Mode (Push button on Front Panel) to allow remote control of switch positions.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.swVersion TEXT R/O StringRange R/O
info.swDate TEXT R/O StringRange R/O
info.partNo TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
position CHOICE EnumRange (0 1 2 3 4)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Input 12VDC)
faults.03 ALARM R/O AlarmFlagRange R/O (Internal 12VDC)
faults.04 ALARM R/O AlarmFlagRange R/O (Internal 5VDC)
faults.05 ALARM R/O AlarmFlagRange R/O (Temperature)
faults.06 ALARM R/O AlarmFlagRange R/O (Switch board)