9.484 Novotronik-GTS5852

This page describes the device driver and the device window for a Novotronik 8x1 Switch from type GTS5852.

The switch has 8 inputs, possible position setting values are 0,1,2...8, position 0 means that no input is connected to the output and all ports are terminated with proper matching impedances.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

The GTS5852 do not need any configuration parameters except the settings for IP address and SNMP communities

The read/write-community strings may be set through the web interface of the device. Factory defaults are 'public' for the read community, 'private' for the write community. Hence a typical address specification for may be 10.0.0.1 public private .

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
info.model TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
position CHOICE EnumRange (0 1 2 3 4 5 6 7 8 9 10 11 12)
faults.01 ALARM R/O AlarmFlagRange R/O (CRK 2000286)
faults.02 ALARM R/O AlarmFlagRange R/O (Manual Control)
faults.03 ALARM R/O AlarmFlagRange R/O (Switch Board)
faults.04 ALARM R/O AlarmFlagRange R/O (K1 read back)
faults.05 ALARM R/O AlarmFlagRange R/O (K2 read back)
faults.06 ALARM R/O AlarmFlagRange R/O (K3 read back)
faults.07 ALARM R/O AlarmFlagRange R/O (24VDC-1)
faults.08 ALARM R/O AlarmFlagRange R/O (24VDC-2)