The ORB-Step-Track device driver is a customized version of the driver for the ND SatCom Steptrack System. There is only one difference of this driver to the original one: It sets a fault if the step track unit falls back to STANDBY for some reason.
For further information about this device driver see the help page of the NDSatCom-Step-Track device driver.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| internal.c | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.d | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.e | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| azimuth | FLOAT | DoubleRange (0.0 .. 0.0) | |
| elevation | FLOAT | DoubleRange (0.0 .. 0.0) | |
| polarization | FLOAT | DoubleRange (0 .. 0) | |
| trackMode | CHOICE | EnumRange (STANDBY REMOTE POSITION MODEL TRACK (NORM) MODEL TRACK (LEARN) MODEL TRACK (PEAKING) SCAN BEACON) | |
| frequency | FLOAT | DoubleRange (0.000 .. 0.000) | |
| state.az | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| state.el | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| state.pl | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| state.mode1 | TEXT | R/O | StringRange R/O |
| state.mode2 | TEXT | R/O | StringRange R/O |
| state.beacon | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| state.moving | BOOLEAN | R/O | BooleanRange R/O (true false) |
| state.limit | BOOLEAN | R/O | BooleanRange R/O (true false) |
| reset | TEXT | StringRange | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (ACU outdoor unit) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (AZ limit) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (EL limit) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (PL limit) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Beacon level) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Volt meter) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Remote/peaking) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Switched to standby) |