9.518 Peak-Blockupconverter

This page describes the device driver and the device window for the for the Peak Blockupconverter Series via SNMP.

It supports 1+1 and 2+1 configurations.

The driver was tested with IBUH without redundancy and UPC SW: 4.55

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.redId TEXT R/O StringRange R/O
info.redType CHOICE R/O EnumRange R/O (1+1 2+1 N+1)
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.lowGain FLOAT SAVE SETUP DoubleRange (0.0 .. 0.0)
config.highGain FLOAT SAVE SETUP DoubleRange (0.0 .. 0.0)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.priority CHOICE SETUP EnumRange (1 2 3 4 5 6 7 8 N/A)
config.hasRedundancy CHOICE SAVE SETUP EnumRange (NO YES)
config.hasUpc CHOICE SAVE SETUP EnumRange (NO YES)
tx.on CHOICE EnumRange (ON OFF)
tx.gain FLOAT DoubleRange (0.0 .. 20.0)
tx.attn FLOAT DoubleRange (0.0 .. 20.0)
meas.extRef BOOLEAN R/O BooleanRange R/O (true false)
location CHOICE EnumRange (A B)
state CHOICE R/O EnumRange R/O (ONLINE STANDBY)
protection CHOICE EnumRange (AUTO MANUAL)
priority CHOICE EnumRange (1 2 3 4 5 6 7 8 N/A)
reset TEXT NOPRESET StringRange
upc.mode CHOICE R/O EnumRange R/O (OFF AUTO MANUAL)
upc.channel CHOICE EnumRange (OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16)
upc.attn FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
upc.Range FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (Unit)
faults.02 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.03 ALARM R/O AlarmFlagRange R/O (Protection)
faults.04 ALARM R/O AlarmFlagRange R/O (Summary)
faults.05 ALARM R/O AlarmFlagRange R/O (UPC)
internal.deltaGain FLOAT DoubleRange (0.0 .. 0.0)
internal.gain FLOAT DoubleRange (0.0 .. 0.0)