9.523 Peak-P700

This page describes the device driver and the device window for the Peak P700 series Up- and Downconverters, but the driver supports currently only the P702 upconverter.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Downconverter.

parameter description
address The device address (decimal) as set at the device's front panel or 0 in RS232 mode.
Serial Remember to set the line parameters for the serial interface connected to the down-converter. It is recommended to operate the device at 9600,N,8,1 .

Communication protocol / Interface type

This device driver requires the Peak protocol. In RS232 mode the device address is fixed to 0 (zero, decimal value). In RS485 mode you can define an address.

Installation

Before you can operate the down-converter with the satnms software, you must prepare the unit to match the interface parameters expected by the software. At the front panel, go to 2. Change -> 3. Rem Control -> and select RS232 or RS485 regarding your cabling. Then select the baud rate (e.g. 9600)

To set the device in remote mode, select 2. Change -> 3. Rem Control -> 1. Disable one time. Selecting 1. Disable again, sets the unit back to front panel control.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.status CHOICE EnumRange (unit not configured unit configured)
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.loFreq FLOAT SETUP DoubleRange (1750.000 .. 13300.000)
config.enableLoFreq CHOICE SETUP EnumRange (ON OFF)
config.buc.loss INTEGER SETUP IntegerRange (0 .. 100)
config.buc.enableLoss CHOICE SETUP EnumRange (ON OFF)
config.buc.10MHz CHOICE SETUP EnumRange (ON OFF)
config.buc.power CHOICE SETUP EnumRange (ON OFF)
tx.on CHOICE EnumRange (OFF ON)
tx.input.level CHOICE EnumRange (-29dBm -26dBm -23dBm -20dBm -19dBm -16dBm -13dBm -10dBm)
tx.output.level CHOICE EnumRange (0dBm -3dBm -6dBm -9dBm -10dBm -13dBm -16dBm -19dBm -20dBm)
tx.frequency FLOAT DoubleRange (12750.000 .. 14500.000)
internal.lbandfreq FLOAT DoubleRange (0.000 .. 0.000)
internal.f1 TEXT R/O StringRange R/O
internal.f2 TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Configuration)
faults.03 ALARM R/O AlarmFlagRange R/O (-5 volts)
faults.04 ALARM R/O AlarmFlagRange R/O (+5 volts)
faults.05 ALARM R/O AlarmFlagRange R/O (+15 volts)
faults.06 ALARM R/O AlarmFlagRange R/O (Tx 10MHz ref)
faults.07 ALARM R/O AlarmFlagRange R/O (L-Band synth)
faults.08 ALARM R/O AlarmFlagRange R/O (UHF synth)
faults.09 ALARM R/O AlarmFlagRange R/O (Tx temp range)