9.552 RFDesign-RSC

This page describes the device driver and the device window for the RFDesign FlexLink-RSC201 2 to 1 RF Switch Unit.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.unitName TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.fwVersion TEXT R/O StringRange R/O
info.dispVersion TEXT R/O StringRange R/O
info.chassisType TEXT R/O StringRange R/O
info.moduleName TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.thresholdLevel INTEGER SETUP IntegerRange (-40 .. 30)
meas.inputPower.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.inputPower.2 INTEGER R/O IntegerRange R/O (0 .. 0)
protection CHOICE EnumRange (MANUAL AUTO)
position CHOICE EnumRange (1 2)
gain INTEGER IntegerRange DIS (0 .. 30)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Unit status)
faults.03 ALARM R/O AlarmFlagRange R/O (Power supply 1)
faults.04 ALARM R/O AlarmFlagRange R/O (Power supply 2)
faults.05 ALARM R/O AlarmFlagRange R/O (Module status)
faults.06 ALARM R/O AlarmFlagRange R/O (RF power overflow)
faults.07 ALARM R/O AlarmFlagRange R/O (Threshold in Slot)
faults.08 ALARM R/O AlarmFlagRange R/O (Protection)
faults.11 ALARM R/O AlarmFlagRange R/O (Amplifier 1)
faults.12 ALARM R/O AlarmFlagRange R/O (Amplifier 2)