This page describes the device driver and the device window for the 2 x 1:1 BDC Redundant System Controllers.
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- Switch parameters.
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
The Speciality do not need any configuration parameters except the settings for the serial interface. The default address is /.
| parameter | description |
|---|---|
| Serial | Remember to set the line parameters for the serial interface connected to the device. The recommended line setting for the use with the sat-nms software is 9600,N,7,1 . |
Remote Control
Default TCP port 6001
Default Address "/"
TCP uses Terminal LF protocol
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.address | TEXT | SAVE SETUP | StringRange |
| protection.1 | CHOICE | EnumRange (MANUAL AUTO) | |
| protection.2 | CHOICE | EnumRange (MANUAL AUTO) | |
| position.1 | CHOICE | EnumRange (A B) | |
| position.2 | CHOICE | EnumRange (A B) | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Unit 1) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Unit 2) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Unit 3) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Unit 4) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Power Supply 1) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Power Supply 2) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Protection 1/2) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Protection 3/4) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Switch 1) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Switch 2) |
| internal.state | TEXT | R/O | StringRange R/O |
| internal.w | HEX | R/O | HexRange R/O (0 .. F) |
| internal.x | HEX | R/O | HexRange R/O (0 .. F) |
| internal.y | HEX | R/O | HexRange R/O (0 .. F) |
| internal.z | HEX | R/O | HexRange R/O (0 .. F) |
| internal.nw | HEX | R/O | HexRange R/O (0 .. F) |
| internal.nx | HEX | R/O | HexRange R/O (0 .. F) |
| internal.ny | HEX | R/O | HexRange R/O (0 .. F) |
| internal.nz | HEX | R/O | HexRange R/O (0 .. F) |
| internal.s1p1 | INTEGER | R/O | IntegerRange R/O (0 .. 1) |
| internal.s1p2 | INTEGER | R/O | IntegerRange R/O (0 .. 1) |
| internal.s2p1 | INTEGER | R/O | IntegerRange R/O (0 .. 1) |
| internal.s2p2 | INTEGER | R/O | IntegerRange R/O (0 .. 1) |
| internal.s1 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.s2 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |